Inspections for the day of: Friday, August 18, 2017.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-00711 General Inspection8/3/20178/18/20178/23/2017 12:28:37 PMAPASS
Permit sign posted. No trackout or issues. Long existing driveway is preserved. No DI bag request due to large drainage area of this inlet.
ESC16-00288 General Inspection8/18/20178/18/20178/18/2017 2:18:04 PM CANC
ESC16-01076 General Inspection8/18/20178/18/20178/18/2017 2:14:27 PM CANC
ESC16-01066 General Inspection8/18/20178/18/20178/18/2017 2:13:29 PM CANC
ESC16-00935 BMP Violation8/18/20178/18/20178/18/2017 2:11:01 PMPFAIL
Disturbed slopes need temporary stabilization due to slow progress of project and approaching wet season.

Maintenance needed on sediment control wattle at bottom of lot.

Need full size dumpster for workers on site.

Site conference scheduled for next week to discuss corrections.
ESC15-01420 General Inspection8/18/20178/18/20178/18/2017 1:59:51 PM CANC
ESC13-00193 General Inspection8/18/20178/18/20178/18/2017 1:59:41 PM PASS
ESC16-00936 BMP Violation8/18/20178/18/20178/18/2017 1:58:33 PMPFAIL
Multiple violations at site despite many site visits and requests.

Corrections:
- clean up trash pile
- provide trash container large enough to contain trash
- forbid spraying concrete washout down hill. - Provide concrete washout pit.
- install sediment control at bottom graded hill and plan for temporary stabilization to prepare for winter.

ESC16-01432 General Inspection8/16/20178/18/20178/18/2017 1:48:50 PMAPART
follow up on correction requests

Trash picked up and new container provided at both Wood River sites. RP Bobby onsite and stated next week the adjacent lot will have perimeter wattles installed and will clean up sidewalk.

Need to service DI bags, confirmed that developer has not agreed to maintain these and that they are the home builders responsibility.
ESC16-01354 General Inspection8/18/20178/18/20178/18/2017 11:14:29 AM PASS
No trackout. Permit signs posted. DI bags installed on surrounding MS4 drains. No fugitive dust or discharges offsite observed
ESC16-00920 Aging Inspection8/18/20178/18/20178/18/2017 10:23:40 AM CANC
ESC16-00919 Aging Inspection8/18/20178/18/20178/18/2017 10:23:18 AM CANC
ESC16-00918 Aging Inspection8/18/20178/18/20178/18/2017 10:21:19 AM CANC
ESC16-00917 Aging Inspection8/18/20178/18/20178/18/2017 10:20:56 AM CANC
ESC16-01618 General Inspection8/18/20178/18/20178/18/2017 8:42:21 AM CANC
rescheduled for site final
ESC16-01621 General Inspection8/18/20178/18/20178/18/2017 8:40:33 AM CANC
ESC16-01108 General Inspection8/18/20178/18/20178/18/2017 8:38:39 AM CANC
ESC16-00921 Aging Inspection8/18/20178/18/20178/18/2017 8:33:01 AM CANC