Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC16-01472 General Inspection8/24/20188/24/20188/27/2018 12:40:05 PM PART
WIP on interior. Hilliside BMPs installed, some section of wattles need stakes re-installed due to movement by sub contractors. Trash around site contained. Silt fence barrier to protect neighbor's yard is installed. Lower section needs maintenance.

No driveway or roof gutters installed yet. Logan alley ROW has two gator guard water bars that channel water to the lower landing area onsite.

Corrections needed:
- resecure damaged or relocated wattles on slope between home and Logan alley.
- re-install silt fence at bottom of installation so that it J-hooks to trap sediment and not allow water to flow off alley to yard below.
- plan to have gutters installed in September or ASAP to prevent runoff flowing over disturbed slopes.
ESC15-00306 General Inspection8/20/20188/24/20188/27/2018 8:12:17 AMACANC
ESC16-01189 Site Final8/24/20188/24/20188/24/2018 3:26:18 PMPCANC
ESC17-00786 Site Final8/23/20188/24/20188/24/2018 3:24:23 PMANR
Home complete but not yet landcaped and gutter is dirty. Will monitor for stabilization and cleanup. BLD finaled and home is occupied.
ESC16-01189 Site Final8/24/20188/24/20188/24/2018 3:14:36 PMPNR
Still need to remove DI bag on Preece. RP dave said he will do it. Rescheduled for two weeks out....
ESC18-00426 Tracking Control8/22/20188/24/20188/24/2018 2:59:08 PMAPASS
Area of concern at south end of subdivision has been swept as requested. Crew on site installing neighborhood fence.

Will need to install sediment protection on the stormdrain on Woodcreek and on Landmark.
ESC18-00476 General Inspection8/24/20188/24/20188/24/2018 2:52:12 PMPPASS
WIP on site work and foundation. Construction entrances installed but are wrong type of rock. No trackout at this time, will need change for Fall DI bags installed on Emerald. No fugitve dust observed. Site is has full silt fence perimeter.
ESC17-01681 DOC - Permit Finaled8/24/20188/24/20188/24/2018 2:49:54 PMPPASS
see ESC18-00476 for ESC permit coverage
ESC17-00510 General Inspection8/24/20188/24/20188/24/2018 2:46:44 PM PASS
WIP at Sterling Park. Entrance and parking lot has curbing but not yet paved. Large compost stockpiles onsite. No windblown dust observed. Water truck also on site. No trackout or discahrges. Surrounding MS4 inlets have sediment protection.
ESC14-01083 General Inspection8/24/20188/24/20188/24/2018 1:39:48 PM PASS
ESC17-01362 General Inspection8/24/20188/24/20188/24/2018 1:39:13 PMPPASS
WIP on frame and installing curbing for roads & parking with site. Construction entrances installed, permit sign posted, trash around perimeter is picked up, concrete washout bins onsite, and water truck available for dust control.

Stockpile of topsoil staged on west side of site has been properly tacified due to planned period of inactivity. Site has been very well managed regard ESC standards.
ESC17-01491 General Inspection8/24/20188/24/20188/24/2018 1:36:53 PMPPASS
Bridge is complete and open. BMPs removed from creek area directly downstream of bridge. No materials or dirty surfaces left on site.

Banks on either side are vegetating, will monitor through Fall.
ESC18-00213 BMP Violation8/23/20188/24/20188/24/2018 12:41:36 PMAPASS
DI bags are now installed in alley ways behind projects. Most trash is contained. Concrete washout with lining is located on lot8- block 14. Needs to have a sign.

Corrections requested were completed. Request to Joey to have loose trash at foundation sites picked up and that sweeping should be done on sites that recently added road mix to driveways.
ESC17-00518 General Inspection8/24/20188/24/20188/24/2018 10:57:49 AM PASS
Exterior work complete. Area around addition has grass. ESC permit finaled. BLD open
ESC17-00518 DOC - Permit Finaled8/24/20188/24/20188/24/2018 10:42:51 AMPPASS
ESC17-00286 Site Final8/24/20188/24/20188/24/2018 10:40:03 AMPPASS
Project now under ESC17-01449. No ESC corrections, this permit finaled.
ESC16-00938 General Inspection8/24/20188/24/20188/24/2018 8:19:49 AM CANC
ESC17-01332 Aging Inspection8/24/20188/24/20188/24/2018 8:04:55 AM DONE
exterior disturbance stabilized. Shop structure complete. BLD is open. ESC permit finaled.
ESC17-01332 DOC - Permit Finaled8/24/20188/24/20188/24/2018 8:02:15 AMPPASS
ESC18-00023 Site Preparation8/20/20188/24/20188/24/2018 8:00:32 AMACANC
10 AM pre construction conference

to be rescheduled.