Inspections for the day of: Thursday, August 4, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-01279 General Inspection8/4/20168/4/20168/5/2016 1:56:48 PM PASS
WIP on townhomes on the east side of Pheasant Tail. Individual SFH permits issued, sites are clean temp BMPs installed including washout and storm drain protection. All construction on the south Caddis culdesac is complete and landscaped - individual ESC permit for those have been closed out.
ESC15-01288 General Inspection8/4/20168/4/20168/5/2016 12:49:16 PM PASS
No activity at site during inspection. BMPs at entrance are installed. No dust issues observed or reported. Permit sign and SWPPP info posted. Approved.
ESC16-00242 General Inspection8/4/20168/4/20168/5/2016 12:27:07 PMPPASS
Heavy duty rock construction entrance installed, permit sign and SWPPP sign posted. Perimeter silt fence in good condtion. No trackout, no fugitive. WIP on foundation work. No corrections requested.
ESC14-00206 General Inspection8/4/20168/4/20168/5/2016 11:45:21 AM PASS
duplicate inspection
ESC15-01355 General Inspection8/3/20168/4/20168/5/2016 11:31:58 AMPPASS
Home complete and landscaped; listed for sale. All permits finaled. No temp BMP removal required due to active construction.
ESC16-00439 General Inspection8/4/20168/4/20168/5/2016 11:25:03 AMPPASS
Work has resumed at Bonneville. No trackout, site is graded below road level and surrounding vegetation has been preserved. Very flat site. Road bases are being prepped. Water truck on site for dust control. Approved.
ESC15-00745 General Inspection8/4/20168/4/20168/5/2016 11:05:00 AMPPASS
Permit and SWPPP sign posted. No trackout to Federal Way, no fugitve observed. Onsite inspecitons conducted by contractor and Micron - no issues reported.
ESC16-00406 Complaint Inspection8/4/20168/4/20168/4/2016 5:01:23 PMPPART
Dust complaint received.

1 water truck on site and two excavators were grubbing/rough grading and moving dirt from two locations within the Highlands Cove subdivision. Initial plans to have onsite water tank were not possible due to location of nearest hydrant.

While onsite the truck is effective at minimalizing the dust, however when filling up water it takes approximately 15-20 minutes - during which excavators continue to operate, making more significant amount of dust during that time and the appearance that there is no dust control at site.

Correction request issued to developer:

- Need to have two water trucks onsite that stagger their loads so that we can have a truck onsite and active while excavation is taking place. The alternative would be to cease excavation when the dust control water truck is filling up.

Site will be inactive tomorrow. Work will resume Saturday and the developer stated there should be two water trucks.

ESC15-00942 General Inspection8/4/20168/4/20168/4/2016 11:45:02 AM PEND
to be finaled with adjacent project completion due to shared BMPs and access area
ESC16-00135 Aging Inspection8/4/20168/4/20168/4/2016 11:43:08 AM PASS
Project complete. No ESC issues. All permits finaled.
ESC16-00135 DOC - Permit Finaled8/4/20168/4/20168/4/2016 11:42:31 AMPPASS
ESC15-01091 General Inspection8/4/20168/4/20168/4/2016 11:42:15 AM PASS
No activity. Site currently stable. Perimeter wattle installed in the runoff location of lot.
ESC16-00975 Site Preparation8/4/20168/4/20168/4/2016 8:33:15 AMPPASS
Installation of pool at active hillside SFH. BMPs already installed. Reviewed washout and trackout rules to contractor. Approved for construction.
ESC16-00966 Site Preparation8/3/20168/4/20168/3/2016 2:23:59 PMAPASS
Larry Phone #: ###-####