Inspections for the day of: Friday, September 25, 2015.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC15-01225 BMP Violation9/25/20159/25/20159/25/2015 4:21:35 PMPPART
no hillside BMPs and dirt tossed down hill - RP stated would be stockpiled on the flat vegetated portion of yard....



Verbal warning to install wattles below excavated and dumped dirt on the hillside. RP stated JH Developer instructed them to place dirt there and compact and re-seed. Will check for BMP installation Monday.
ESC15-00338 Aging Inspection9/25/20159/25/20159/25/2015 4:19:52 PM PASS
Home complete, cleaned, and stabilized. ESC permit conditions satisfied.
ESC15-00338 DOC - Permit Finaled9/25/20159/25/20159/25/2015 4:19:32 PMPPASS
ESC15-00464 Aging Inspection9/25/20159/25/20159/25/2015 3:08:21 PM PASS
Stairway and remodel work complete. Site cleaned and stabilized. All permits finaled.
ESC15-00464 DOC - Permit Finaled9/25/20159/25/20159/25/2015 3:07:00 PMPPASS
ESC13-00213 General Inspection9/25/20159/25/20159/25/2015 3:02:21 PM CANC
ESC15-00729 Conference9/25/20159/25/20159/25/2015 2:52:14 PMPPASS
Harris Ranch North project update:

- No trackout at site to Barber Dr, permit and SWPPP info posted, silt fence along bottom of site is containing sediment. No significant fugitive dust issues observed or reported to date. Syman Co. inspects the upper portions development on Tuesdays, scheduled to ride-a-long next week.

Discussion with Chad Hamel with Hunter Homes to get update:
- dewatering and compaction water is being stored in a pond above Barber Dr. Area is surrounded by silt fence. Future water tank is scheduled to be built this winter.

- Graded hillsides are compacted and tracked perpendicular to slope contours. Syman Co is to install wattles incrementally on the cut hillsides, which will be hydroseeded/tacified in this fall.

Project got approval from Army Corps to install box culvert in Squaw Creek/ Council Springs for stormwater drainage. Currently area delineated by silt fence. SF will be removed and work will begin in area next. HH to submit copy of 404 permit permission to City ESC.

No corrections at this time.
ESC15-00477 BMP Violation9/25/20159/25/20159/25/2015 2:27:25 PMPFAIL
Follow up inspection of clean up and BMP installation in response to CN 9/24:



Reinspected site at 1:30 PM with ESC Coordinator. Observations:

- silt fence was installed along edge of pavement, but was not properly trenched in. Notified installer to come fix and make sure it is not loose at bottom
- no sweeping of sidewalk or road had been completed at time of inspection. Loose dirt, rocks, broken gravel bags, and fine material from stucco washout were not cleaned up.

At end of inspection, Curtis Clean Sweep truck arrived. I coordinated moving worker vehicles, removed gravel bags from gutter, and swept sidewalk to ensure the site would get cleaned up.

Corrections needed:
1. Provide stucco contractor a washout container
2. Have portapot company move toilet off sidewalk and at minimum 50 ft away from stormdrain. Currently located directly next to stormdrain, not staked down. Spill risk.
3. Finish sweeping sidewalk
4. Install construction entrance or fence off access to vehicles to prevent track out
5. Weekly housekeeping and stormwater pollution prevention should now occur at least 1x per week till end of project.

Spent nearly 1 hour at site. Re-inspection fee $55 assessed to Syringa Homes.
ESC14-00809 General Inspection9/25/20159/25/20159/25/2015 11:50:57 AM PASS
WIP. Minimal trackout from unpaved slope driveway is being sweeping periodically. Workers parking on the street. No fugitive dust observed, working on the frame. Approved.
ESC13-00230 General Inspection9/25/20159/25/20159/25/2015 11:35:29 AM PASS
5 SFHs currently in progress in RH#5 and 2 open lots. DI bags in subdivision storm drains have been maintained and have remaining capactity. Streets and gutters free of loose sediment or material spills. Lined washout located on Grand Prairie. No corrections at this time.
ESC15-01054 Site Preparation9/24/20159/25/20159/25/2015 11:08:52 AMAPASS
Clint Phone #: ###-####

Permit sign posted. Tahoe SFHs on Brookridge are having foundations laid, dirt being stockpiled across street to the east. No trackout. DI bags installed, and lined washout provided. No significant wind blown trash issues at this time.
ESC15-00106 General Inspection9/25/20159/25/20159/25/2015 10:18:13 AM PASS
ESC15-00105 General Inspection9/25/20159/25/20159/25/2015 9:46:16 AM PASS
ESC15-00347 Aging Inspection9/25/20159/25/20159/25/2015 9:11:12 AM PASS
Building demolished and site has been cleaned of debris and sediment. No futher construction. No ESC issues. Permit finaled.
ESC15-00347 DOC - Permit Finaled9/25/20159/25/20159/25/2015 9:10:09 AMPPASS
ESC15-00330 Aging Inspection9/25/20159/25/20159/25/2015 8:56:37 AM PASS
Home complete, materials cleaned up, yard is landscaped/stabilized. Permit conditions satisfied. No temp BMP removal due to ongoing projects in RH#5
ESC15-00330 DOC - Permit Finaled9/25/20159/25/20159/25/2015 8:55:24 AMPPASS