Inspections for the day of: Thursday, March 2, 2017.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMelissa Jannusch
TitleEROSION INSPECTOR
Phone #789-3996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-00055 Site Preparation3/2/20173/2/20173/2/2017 4:38:06 PMPPASS
okay to start
ESC13-00193 General Inspection3/2/20173/2/20173/2/2017 2:54:48 PM PASS
No WIP. silt fence still needs repair.
ESC16-00757 Site Final3/2/20173/2/20173/2/2017 2:44:52 PMPPASS
ESC16-00757 Aging Inspection3/2/20173/2/20173/2/2017 2:44:37 PM PASS
Demolition complete. Okay to final.
ESC16-00807 Aging Inspection3/2/20173/2/20173/2/2017 2:38:35 PM PASS
No esc issues.
ESC17-00001 Tracking Control2/21/20173/2/20173/2/2017 2:14:38 PMPPART
Piles have been moved. There is still significant trackout along some of Hiawatha Dr.
ESC16-00879 General Inspection3/2/20173/2/20173/2/2017 1:40:51 PMPPASS
SWPPP binder up to date. No corrections requested.
ESC16-00653 Site Final3/2/20173/2/20173/2/2017 1:30:40 PMPPASS
Okay to final. No more earth work will be occurring.
ESC17-00185 Site Preparation3/2/20173/2/20173/2/2017 12:59:54 PMPPASS
Met with RP Doyle on site. Discussed trackout control, trash containment, and runoff prevention. Sign is posted.
Okay to start.
ESC16-00844 Aging Inspection3/2/20173/2/20173/2/2017 11:23:00 AM FAIL
Trackout onto sidewalk between Trailwood to Honeycomb (Parkcenter 3908,3920,3936,3945,3954,3962,3970,3982). Trackout on honeycomb.
ESC16-01561 Random Inspection3/2/20173/2/20173/2/2017 11:02:47 AMPPASS
Dewatering operation update: Water has filled the site designated for sheet flow and infiltration of the dewatering water as well as the contingency settling site. Two overflow spill ways have been installed that are discharging water into the creek adjacent to the site.

The first over flow spill way is comprised of a dirt berm channel with three wattles to slow water flow and catch sediment. The discharge appears clean with no plume in the creek visible.

The other overflow set up is comprised of a wattle slowing discharge from the site. The water then enters a pipe. The outlet to the pipe has plastic sheeting underneath it to prevent scour/erosion at the outlet. There is another wattle placed at the bottom of the plastic sheet to slow the water and catch the sediment before the discharge enters the stream. The water appears clean with no plume visible.

The RP should update the SWPPP to reflect changes to the dewatering plan. At the end of the dewatering operation ensure the BMPs are cleaned up so they do not enter the stream. Left message with RP.
ESC16-00965 Aging Inspection3/2/20173/2/20173/2/2017 9:55:18 AM PASS
No issues observed.
ESC15-00556 General Inspection3/2/20173/2/20173/2/2017 9:45:11 AM PASS
WIP. Concrete washout in good condition. DI bags okay. No significant trackout. Dirt piles are back from sidewalk and contained on site. No corrections requested.
ESC16-01390 Site Preparation2/16/20173/2/20173/1/2017 8:26:44 AMPCANC