Inspections for the day of: Thursday, March 30, 2017.
Number of inspections: 22
Percentage of inspections complete: 95 %
Percentage of inspections not complete: 5 %
Contact Information
InspectorMelissa Jannusch
TitleEROSION INSPECTOR
Phone #789-3996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC16-01213 Tracking Control3/21/20173/28/2017 P 
ESC15-00853 General Inspection3/30/20173/30/20173/31/2017 1:41:22 PM PASS
Sign posted. No trackout to hill rd. project ok.
ESC16-01093 General Inspection3/30/20173/30/20173/31/2017 12:28:21 PMPPASS
Sediment is contained. No runoff. Perimeter wattles are ok. Sign is posted. No corrections.
ESC14-00788 Complaint Inspection3/30/20173/30/20173/30/2017 4:58:02 PMPPEND
Swale overtopped and caused failure of the slope. Water and sediment discharged onto warm springs ave. RP sand bagging and filling breach. Plans to clean up sediment on warmsprings. Swale will need to be reconfigured to ensure the overflow is lower than the top elevation of the pond.
The private dirt road next to the subdivision is washing out not part of the subdivision so RP does not have responsibility for the road.
ESC15-00976 General Inspection3/30/20173/30/20173/30/2017 3:35:29 PM CANC
ESC16-00958 Site Final3/30/20173/30/20173/30/2017 3:35:02 PMPPASS
ESC16-00958 Aging Inspection3/30/20173/30/20173/30/2017 3:34:48 PM PASS
Project complete. Soil stable okay to final.
ESC16-01275 General Inspection3/30/20173/30/20173/30/2017 3:32:11 PMPPASS
No ESC issues observed.
ESC16-01091 General Inspection3/30/20173/30/20173/30/2017 3:31:59 PM PASS
No ESC issues observed.
ESC15-00731 General Inspection3/30/20173/30/20173/30/2017 3:31:03 PM PASS
WIP on interior and exterior. No issues.
ESC16-00849 General Inspection3/30/20173/30/20173/30/2017 3:30:26 PM PASS
Vertical WIP. Silt fence ok.
ESC16-00936 Complaint Inspection3/30/20173/30/20173/30/2017 2:32:03 PMPPASS
See ESC 16-00935 for complaint inspection. This is the site above where the drainage issues occurred.
ESC16-00935 Complaint Inspection3/30/20173/30/20173/30/2017 2:29:45 PMPFAIL
Met onsite with RP. The slope did not fail. The silt fence at the bottom of the site failed and overflowed water and dirt into the downhill property. The portion of the silt fence that was removed to allow for the building of the fence was not where the overflow occurred.
RP and crew are currently
1) Replacing wattles that were located in the road way to slow down overland flows
2) Dig a channel to send water into the vegetated perimeter and away from homeowner’s property
3) Removed sediment from behind remaining silt fence
RP has spoken with the homeowner and has committed to cleaning the sediment out of his garage area.
They hope to finish the fence in the next few days.
ESC16-00612 Aging Inspection3/30/20173/30/20173/30/2017 11:30:17 AM PASS
WIP on interior and exterior. No violations observed.
ESC16-00695 Aging Inspection3/30/20173/30/20173/30/2017 11:30:07 AM PASS
WIP on interior and exterior. No violations observed.
ESC16-00990 General Inspection3/30/20173/30/20173/30/2017 10:47:52 AM PASS
No ESC issues observed.
ESC16-00853 General Inspection3/30/20173/30/20173/30/2017 10:46:31 AMPPASS
Trackout has been cleaned up.
ESC16-01536 Site Preparation3/30/20173/30/20173/30/2017 10:20:43 AMPPASS
Okay to start. Concrete washout still needs maintenance.
ESC16-00439 General Inspection3/30/20173/30/20173/30/2017 10:00:42 AMAPASS
No WIP today due to rainy conditions. No trackout. DI bags ok. Concrete washout in use. No corrections.
ESC14-00206 General Inspection3/30/20173/30/20173/30/2017 9:49:12 AM PASS
Work has not resumed. Equipment on site. DI bags ok. No ESC issues observed.
ESC04-00247 DOC - Permit Finaled3/30/20173/30/20173/30/2017 8:37:58 AMPPASS
Project complete
ESC03-01491 DOC - Permit Finaled3/30/20173/30/20173/30/2017 8:37:25 AMPPASS
Project complete