ESC16-01213
| Tracking Control | 3/21/2017 | 3/28/2017 | | P | |
|
|
|
ESC15-00853
| General Inspection | 3/30/2017 | 3/30/2017 | 3/31/2017 1:41:22 PM | | PASS |
|
|
Sign posted. No trackout to hill rd. project ok.
|
ESC16-01093
| General Inspection | 3/30/2017 | 3/30/2017 | 3/31/2017 12:28:21 PM | P | PASS |
|
|
Sediment is contained. No runoff. Perimeter wattles are ok. Sign is posted. No corrections.
|
ESC14-00788
| Complaint Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 4:58:02 PM | P | PEND |
|
|
Swale overtopped and caused failure of the slope. Water and sediment discharged onto warm springs ave. RP sand bagging and filling breach. Plans to clean up sediment on warmsprings. Swale will need to be reconfigured to ensure the overflow is lower than the top elevation of the pond. The private dirt road next to the subdivision is washing out not part of the subdivision so RP does not have responsibility for the road.
|
ESC15-00976
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 3:35:29 PM | | CANC |
|
|
|
ESC16-00958
| Site Final | 3/30/2017 | 3/30/2017 | 3/30/2017 3:35:02 PM | P | PASS |
|
|
|
ESC16-00958
| Aging Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 3:34:48 PM | | PASS |
|
|
Project complete. Soil stable okay to final.
|
ESC16-01275
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 3:32:11 PM | P | PASS |
|
|
No ESC issues observed.
|
ESC16-01091
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 3:31:59 PM | | PASS |
|
|
No ESC issues observed.
|
ESC15-00731
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 3:31:03 PM | | PASS |
|
|
WIP on interior and exterior. No issues.
|
ESC16-00849
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 3:30:26 PM | | PASS |
|
|
Vertical WIP. Silt fence ok.
|
ESC16-00936
| Complaint Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 2:32:03 PM | P | PASS |
|
|
See ESC 16-00935 for complaint inspection. This is the site above where the drainage issues occurred.
|
ESC16-00935
| Complaint Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 2:29:45 PM | P | FAIL |
|
|
Met onsite with RP. The slope did not fail. The silt fence at the bottom of the site failed and overflowed water and dirt into the downhill property. The portion of the silt fence that was removed to allow for the building of the fence was not where the overflow occurred. RP and crew are currently 1) Replacing wattles that were located in the road way to slow down overland flows 2) Dig a channel to send water into the vegetated perimeter and away from homeowner’s property 3) Removed sediment from behind remaining silt fence RP has spoken with the homeowner and has committed to cleaning the sediment out of his garage area. They hope to finish the fence in the next few days.
|
ESC16-00612
| Aging Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 11:30:17 AM | | PASS |
|
|
WIP on interior and exterior. No violations observed.
|
ESC16-00695
| Aging Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 11:30:07 AM | | PASS |
|
|
WIP on interior and exterior. No violations observed.
|
ESC16-00990
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 10:47:52 AM | | PASS |
|
|
No ESC issues observed.
|
ESC16-00853
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 10:46:31 AM | P | PASS |
|
|
Trackout has been cleaned up.
|
ESC16-01536
| Site Preparation | 3/30/2017 | 3/30/2017 | 3/30/2017 10:20:43 AM | P | PASS |
|
|
Okay to start. Concrete washout still needs maintenance.
|
ESC16-00439
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 10:00:42 AM | A | PASS |
|
|
No WIP today due to rainy conditions. No trackout. DI bags ok. Concrete washout in use. No corrections.
|
ESC14-00206
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 9:49:12 AM | | PASS |
|
|
Work has not resumed. Equipment on site. DI bags ok. No ESC issues observed.
|
ESC04-00247
| DOC - Permit Finaled | 3/30/2017 | 3/30/2017 | 3/30/2017 8:37:58 AM | P | PASS |
|
|
Project complete
|
ESC03-01491
| DOC - Permit Finaled | 3/30/2017 | 3/30/2017 | 3/30/2017 8:37:25 AM | P | PASS |
|
|
Project complete
|