Inspections for the day of: Wednesday, March 8, 2017.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMelissa Jannusch
TitleEROSION INSPECTOR
Phone #789-3996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC16-01645 General Inspection3/7/20173/8/20173/10/2017 10:17:38 AMAFAIL
3304 S Cadet Ave: Work has been started. Concrete slurry on dirt. No inlet protection in the drop inlet, but there are two sand bags in the gutter. The sand bags are not providing adequate filtering.
Corrections requested: Install inlet protection, concrete washout before more concrete work occurs.
Left message with RP requesting changes. Follow up next week
ESC16-01187 BMP Violation3/7/20173/8/20173/9/2017 3:15:26 PMPFAIL
Work has been occurring on foundation. No WIP during inspection No site preparation was scheduled. The road and sidewalk are clean. Sign posted. The perimeter wattle has not been installed. RP did not answer and mailbox is full. No answer from owner. Need to install perimeter wattle to pass site inspection.
ESC16-00800 Site Final3/8/20173/8/20173/8/2017 11:13:19 AMAPASS
ESC16-00800 Aging Inspection3/8/20173/8/20173/8/2017 11:12:52 AM PASS
Okay to final.
ESC16-00975 General Inspection3/8/20173/8/20173/8/2017 10:55:59 AMAPASS
No ESC issues observed
ESC16-00975 General Inspection3/8/20173/8/20173/8/2017 10:55:45 AM PASS
No ESC issues observed
ESC15-01543 General Inspection3/8/20173/8/20173/8/2017 10:45:06 AM PASS
ESC11-00879 BMP Violation3/1/20173/8/20173/8/2017 10:43:58 AMAFAIL
Concrete slurry on undeveloped lot. Correction request: clean up slurry. Use concrete washout in future.
ESC16-00497 Aging Inspection3/8/20173/8/20173/8/2017 10:32:28 AM PASS
No ESC violations observed.
ESC15-00142 General Inspection3/8/20173/8/20173/8/2017 9:50:30 AM PASS
BLD permit still open. No ESC violations observed
ESC16-00301 Site Final3/8/20173/8/20173/8/2017 9:40:39 AMAPASS
ESC16-00525 Site Final3/8/20173/8/20173/8/2017 9:31:49 AMAPASS
ESC15-01288 General Inspection3/8/20173/8/20173/8/2017 9:04:05 AMPPASS
Minor correction request: Clean sediment out of gutters.
ESC17-00088 Site Preparation3/7/20173/8/20173/8/2017 9:02:21 AMAPASS
okay to start