Inspections for the day of: Friday, June 16, 2017.
Number of inspections: 29
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMelissa Jannusch
TitleEROSION INSPECTOR
Phone #789-3996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC16-01476 Complaint Inspection6/16/20176/16/20176/21/2017 8:39:12 AMPPASS
Trash contained, no trackout, signs are posted. Concrete slurry in dirt alleyway. Slurry not in danger of running off into a storm drain. Alley is to be paved soon as well. Area is flat large field behind project. No corrections issued at the time of inspection.
ESC16-01167 General Inspection6/16/20176/16/20176/19/2017 12:48:12 PM PASS
WIP on Jefferson st re paving. No ESC issues observed.
ESC15-01210 General Inspection6/16/20176/16/20176/19/2017 12:42:02 PM PASS
WIP on SFHs. No trackout. Trash contained. Subdivision BMPs okay.
ESC17-00270 General Inspection6/15/20176/16/20176/19/2017 8:41:27 AMACANC
follow up inspection; check wattles
ESC16-01301 Aging Inspection6/16/20176/16/20176/16/2017 4:34:22 PM CANC
ESC16-01141 General Inspection6/16/20176/16/20176/16/2017 4:34:07 PM PASS
ESC16-01340 Site Final6/16/20176/16/20176/16/2017 4:32:28 PMPPASS
ESC16-01344 Site Final6/16/20176/16/20176/16/2017 4:30:51 PMPPASS
ESC16-01344 Aging Inspection6/16/20176/16/20176/16/2017 4:30:37 PM PASS
ESC16-01047 Site Final6/16/20176/16/20176/16/2017 4:29:41 PMPPASS
ESC16-00853 General Inspection6/16/20176/16/20176/16/2017 4:27:42 PM PEND
Trackout onto Echo court. Called RP for Lasher construction Brian Murdoch and requested that he get a standalone ESC staging permit for 3309
Echo ct. since this site has had multiple trackout infractions caused by both Lasher construction and Sunrise construction who is currently building next door. This will ensure corrective actions are written for the correct site, company, and RP. I told the RP that the fee for this ESC staging permit can be applied toward the future ESC permit that will be attached to the building permit for the SFH that will be built on this site.

Called RP for adjacent lot 3327 Echo and spoke with RP Justin Reynolds who takes responsibility for the current trackout violation and will be responsible for cleaning it. I told him that Lasher construction will be getting an ESC permit for the site and that he should disallow his contractors from entering his site through Lasher’s site. He has placed several cones with caution tape in attempt to keep workers out of the vacant site but they were recently moved.

Justin also says the excavator is the same for both companies which may be adding to the confusion for the subcontractors.

Having 3309 Echo court get an ESC permit should help ensure that corrective actions reach the right RP and keep Echo court free from trackout.

Actions to be taken:

3327 Echo ct. with RP Justin Reynold will clean trackout in Echo court. RP will tell staff to not enter the lot through the 3309 Echo ct. Follow up next week.

3309 Echo ct. with RP Bryan Murdoch will apply for ESC staging permit. The fee for this permit can be applied for a future ESC building permit on this site. Follow up on permit application next week.
MIS17-00196 ESC-Conference6/16/20176/16/20176/16/2017 4:26:29 PMPPEND
Trackout onto Echo court. Called RP for Lasher construction Brian Murdoch and requested that he get a standalone ESC staging permit for 3309 Echo ct. since this site has had multiple trackout infractions caused by both Lasher construction and Sunrise construction who is currently building next door. This will ensure corrective actions are written for the correct site, company, and RP. I told the RP that the fee for this ESC staging permit can be applied toward the future ESC permit that will be attached to the building permit for the SFH that will be built on this site.

Called RP for adjacent lot 3327 Echo and spoke with RP Justin Reynolds who takes responsibility for the current trackout violation and will be responsible for cleaning it. I told him that Lasher construction will be getting an ESC permit for the site and that he should disallow his contractors from entering his site through Lasher’s site. He has placed several cones with caution tape in attempt to keep workers out of the vacant site but they were recently moved.

Justin also says the excavator is the same for both companies which may be adding to the confusion for the subcontractors.

Having 3309 Echo court get an ESC permit should help ensure that corrective actions reach the right RP and keep Echo court free from trackout.

Actions to be taken:

3327 Echo ct. with RP Justin Reynold will clean trackout in Echo court. RP will tell staff to not enter the lot through the 3309 Echo ct. Follow up next week.

3309 Echo ct. with RP Bryan Murdoch will apply for ESC staging permit. The fee for this permit can be applied for a future ESC building permit on this site. Follow up on permit application next week.
ESC16-01346 Site Final6/16/20176/16/20176/16/2017 4:04:57 PMPPASS
ESC16-01346 Aging Inspection6/16/20176/16/20176/16/2017 4:04:47 PM PASS
Ok to final ESC permit
ESC17-00411 Site Preparation6/16/20176/16/20176/16/2017 2:29:27 PMPPASS
Phone #: ###-#### Inspection requested via web by Braxton Hansen
ESC17-00478 Site Preparation6/16/20176/16/20176/16/2017 2:29:14 PMPPASS
Phone #: ###-#### Inspection requested via web by Braxton Hansen
ESC17-00512 Site Preparation6/16/20176/16/20176/16/2017 2:29:03 PMPPASS
Phone #: ###-#### Inspection requested via web by Braxton Hansen
ESC16-01348 Aging Inspection6/16/20176/16/20176/16/2017 12:28:33 PM CANC
ESC16-01582 General Inspection6/14/20176/16/20176/16/2017 12:27:52 PMACANC
ESC16-00948 General Inspection6/14/20176/16/20176/16/2017 12:24:35 PMAPART
Some trackout on interior roads. DI bags okay. No concrete slurry visable on the ground or areas that can runoff the site.
ESC15-00853 General Inspection6/15/20176/16/20176/16/2017 11:21:50 AMAPART
Dumpster is one site. Wattles are one site. DI bags are clean. Gutters are clean. Trackout still on interior road. Trackout onto Hill road.
Correction: clean trackout on interior and exterior road
RP has sweeper scheduled for Monday.
ESC16-01570 General Inspection6/16/20176/16/20176/16/2017 10:11:08 AMPPASS
WIP on interior and exterior. No trackout, trash is contained. No ESC issues observed.
ESC16-00365 Site Final6/14/20176/16/20176/16/2017 10:06:56 AMPPASS
Landscaped, no temp BMPs, no trash okay to final ESC.
ESC16-00159 BMP Violation6/16/20176/16/20176/16/2017 10:02:19 AMPPEND
RP Clint Wall got a new phone so the correction requests were not reaching him. I have recieved RP Clint's new phone number and requested the corrections. He is starting work on corrections currently. Will follow up monday.
ESC17-00322 Site Preparation6/15/20176/16/20176/16/2017 9:34:14 AMAPASS
Clint Phone #: ###-####
ESC16-01143 BMP Violation6/16/20176/16/20176/16/2017 9:34:00 AMPPEND
RP Clint Wall got a new phone so the correction requests were not reaching him. I have recieved RP Clint's new phone number and requested the corrections. He is starting work on corrections currently. Will follow up monday.
ESC17-00388 Site Preparation6/15/20176/16/20176/15/2017 1:46:42 PMAPASS
Erby Phone #: ###-####
ESC17-00429 Site Preparation6/15/20176/16/20176/15/2017 1:46:32 PMAPASS
Erby Phone #: ###-####
ESC17-00430 Site Preparation6/15/20176/16/20176/15/2017 1:46:23 PMAPASS