ESC18-01210
| General Inspection | 1/22/2019 | 1/23/2019 | 1/28/2019 10:56:27 AM | P | PASS |
|
|
Dewatering water is clear and clean, discharged into ACHD drain. Well maintained rock entrance. Crew is on site tyeing rebar, did not see washout, will be needed for pour.
|
ESC16-01395
| General Inspection | 1/23/2019 | 1/23/2019 | 1/24/2019 2:12:18 PM | | PASS |
|
|
Front is landscaped and stable. No work has begun in rear.
|
ESC18-00348
| Aging Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 2:22:36 PM | | PASS |
|
|
No disturbances outside of fence.
|
ESC18-01376
| BMP Violation | 1/23/2019 | 1/23/2019 | 1/23/2019 1:50:30 PM | P | FAIL |
|
|
Trackout and washout dumped onto ground. Corections needed: Clean trackout, install construction entrance and stabalized parking area. Remove and clean old washout, install new washout with liner.
|
ESC18-01375
| BMP Violation | 1/23/2019 | 1/23/2019 | 1/23/2019 1:50:16 PM | P | FAIL |
|
|
Trackout and washout dumped onto ground. Corections needed: Clean trackout, install construction entrance and stabalized parking area. Remove and clean old washout, install new washout with liner.
|
ESC18-00659
| BMP Violation | 1/23/2019 | 1/23/2019 | 1/23/2019 1:50:02 PM | P | FAIL |
|
|
Trackout and washout dumped onto ground. Corections needed: Clean trackout, install construction entrance and stabalized parking area. Remove and clean old washout, install new washout with liner.
|
ESC18-00320
| Aging Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 12:57:58 PM | | PASS |
|
|
No disturbances.
|
ESC17-01718
| Site Final | 1/22/2019 | 1/23/2019 | 1/23/2019 12:29:30 PM | P | PASS |
|
|
|
ESC17-01739
| General Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 12:01:07 PM | | CANC |
|
|
|
ESC17-01739
| DOC - Permit Finaled | 1/23/2019 | 1/23/2019 | 1/23/2019 12:01:01 PM | P | PASS |
|
|
Work completed, building permit still open waiting on life and fire finals.
|
ESC17-01792
| General Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 11:59:56 AM | | DONE |
|
|
No activity, gate was locked.
|
ESC17-00990
| Aging Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 11:48:37 AM | | PASS |
|
|
No disturbances. OK to final when building permit closed.
|
ESC18-00350
| Aging Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 11:16:00 AM | | PASS |
|
|
work completed.
|
ESC17-01783
| General Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 10:51:07 AM | | PASS |
|
|
WIP. No ESC issues.
|
ESC17-00013
| General Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 10:46:19 AM | | PASS |
|
|
Few foundations poured, framers have begun on first home. Old washouts were cleaned and removed, new one dug. Backfill will be moved onto Harris property for farming alfalfa.
|
ESC16-00489
| General Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 10:14:39 AM | | PASS |
|
|
Few lots remaining. DI protection still installed.
|
ESC17-01749
| General Inspection | 1/23/2019 | 1/23/2019 | 1/23/2019 9:55:25 AM | | PASS |
|
|
Workers all parked in street. No garbage or ESC issues at site.
|
ESC17-00791
| General Inspection | 1/22/2019 | 1/23/2019 | 1/23/2019 9:41:05 AM | P | PART |
|
|
No new activity. Some rills going around and under wattle. Rilling in perimeter ditch, sediment going into protected drain.
|