Inspections for the day of: Friday, November 1, 2019.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMichael Zawacki
TitleEROSION INSPECTOR
Phone #208-473-8333
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC19-00861 General Inspection11/1/201911/1/201911/6/2019 12:50:44 PMPPASS
Realigning creek started from north working sw through site. New channel is defined, more in the northern section of site. Some rock armoring has been installed on curves. Evidence of sprayed water for compaction. Strip of land grubbed parrallel to creek, most of site still has natural cover. No esc issues, work area is isolated.
ESC18-00900 General Inspection11/1/201911/1/201911/6/2019 12:14:08 PMPPART
Trucks running laps hauling fill. Some tracking aT BOTH ENTRANCES.
ESC18-00358 General Inspection11/1/201911/1/201911/6/2019 8:39:28 AMPCANC
ESC18-01636 General Inspection11/1/201911/1/201911/4/2019 11:49:22 AMPPASS
Met with Rex from Knife river while at site.
They are waiting for lab results for water in pond. If it comes back clean they will pump it out into the field to the east.
Contanimated dirt pile still on site, if test come back ok it will be used as fill.
They are planning to pave and do curb and gutter this fall, not sure if it will get done in time.
Three ponds are planned on getting built on south side of warm springs and all excavated material used for fill.
Will need to set up meeting with all parties to see what plan is, nothing has any dates set yet.
ESC18-01626 Site Final10/31/201911/1/201911/4/2019 11:07:56 AMPPASS
ESC18-00177 General Inspection11/1/201911/1/201911/4/2019 10:58:40 AM PASS
WIP on both framing and foundations.
Lined concrete washout on site and in use.
Trash contractor on site clearing trash boxes. Site is clean in regards to trash.
Lots of dirt tracked inside site, none leaving.
Silt fence/ trash fence protecting creek.
ESC16-00625 Site Final10/29/201911/1/201911/4/2019 8:27:07 AMPPASS
ESC18-01711 Aging Inspection11/1/201911/1/201911/1/2019 1:34:47 PM PASS
No outside disturbances.
ESC18-00141 General Inspection11/1/201911/1/201911/1/2019 1:26:34 PM PASS
Area clean and stable.
OK to close when building permit done.
ESC17-00640 General Inspection11/1/201911/1/201911/1/2019 1:26:03 PM DONE
ESC18-00844 General Inspection11/1/201911/1/201911/1/2019 11:44:33 AM PASS
Lot is contained, no esc issues.
ESC19-00927 General Inspection11/1/201911/1/201911/1/2019 11:40:13 AMPPASS
Crew on site doing horizontal boring. Boulders for wall staged on site.
Nothing leaving site.
ESC18-00498 General Inspection11/1/201911/1/201911/1/2019 11:29:14 AM PASS
Work on one home in phase. No issues, job trailer in phase.
ESC18-00946 General Inspection11/1/201911/1/201911/1/2019 11:20:46 AM PASS
No new activity at site.
Weed growth and cover. Water conveyance system still on lot, silt fence is gone.
ESC19-00241 General Inspection11/1/201911/1/201911/1/2019 11:14:28 AMPPASS
WIP on framing.
All concrete work done until spring. Plan is to have framing done and work on interior all winter.
Seepage beds completed, 10" pit run all across site to have it free drain during winter. Two exits, sweeping up weekly.
ESC17-00190 General Inspection11/1/201911/1/201911/1/2019 10:56:47 AM PASS
No new building activity.
ESC19-00994 General Inspection11/1/201911/1/201911/1/2019 10:56:16 AMPPASS
Met with Scott on site. Is having the hillsides watered and retracked with a bigger machine, smaller machine was having issues getting up hills.
Syman should start hydroseeding next week. Let him know to have wattle ends overlap and have stakes at 5' intervals.
ESC18-01733 Aging Inspection11/1/201911/1/201911/1/2019 10:17:27 AM CANC
ESC18-01733 DOC - Permit Finaled11/1/201911/1/201911/1/2019 10:17:22 AMPPASS
ESC17-01287 General Inspection11/1/201911/1/201911/1/2019 10:06:37 AM PASS
ESC15-00857 General Inspection11/1/201911/1/201911/1/2019 10:02:15 AM PASS
Area is clean, rp repaired silt fence at bottom.
Some diirt on road at bottom from phase 10
ESC19-00396 General Inspection11/1/201911/1/201911/1/2019 9:46:17 AMPPART
Message sent to Clint.
Some trash blown into silt fence.
Areas of silt fence under load and area not trenched in.
ESC18-01447 General Inspection11/1/201911/1/201911/1/2019 9:30:21 AMPPASS
Hillside has been hydroseeded and tackified. Washout cleaned and ecopan now on site. Mini excavator doing rock work on perimeter of lot.