ESC17-01132
| General Inspection | 11/19/2018 | 11/19/2018 | 11/20/2018 12:33:20 PM | | FAIL |
|
|
One of the concrete trucks didn't use washout and dumped onto ground, still wet at time of inspection. Foreman is going to have excavator scrape and clean area. Curbing still needed on right of way at Jefferson, they are waiting for ACHD approval. Most of disturbed area is below grade, wattles installed where it is even with road.
|
ESC16-00242
| General Inspection | 11/19/2018 | 11/19/2018 | 11/20/2018 9:57:05 AM | | PASS |
|
|
Did quick site survey. All areas clean, BMPs in place. No noted ESC issues. WIll schedule inspection for campus in spring.
|
ESC17-00155
| Aging Inspection | 11/19/2018 | 11/19/2018 | 11/20/2018 8:44:38 AM | | CANC |
|
|
|
ESC16-00741
| General Inspection | 11/19/2018 | 11/19/2018 | 11/19/2018 3:00:56 PM | | PASS |
|
|
New blocksom was installed at 5th & Main intersection. Witches hat installed at 6th & Idaho. Some sand is stored on 5th, looks like it is being brought into building site for compaction.
|
ESC18-01478
| Site Final | 11/19/2018 | 11/19/2018 | 11/19/2018 2:29:17 PM | P | PASS |
|
|
|
ESC18-01477
| Site Final | 11/19/2018 | 11/19/2018 | 11/19/2018 2:29:04 PM | P | PASS |
|
|
|
ESC18-00176
| General Inspection | 11/19/2018 | 11/19/2018 | 11/19/2018 2:22:19 PM | P | PART |
|
|
Silt fence on south west perimeter needs to be trenched. No inlet protection at Broadway intersection. Construction entrance is round river rock not crushed.
|
ESC18-01275
| Site Final | 11/19/2018 | 11/19/2018 | 11/19/2018 2:13:18 PM | P | PASS |
|
|
Future location of oil change shop.
|
ESC18-01274
| Site Final | 11/19/2018 | 11/19/2018 | 11/19/2018 2:13:03 PM | P | PASS |
|
|
Future location of oil change shop.
|
ESC18-01366
| General Inspection | 11/19/2018 | 11/19/2018 | 11/19/2018 12:29:38 PM | P | PASS |
|
|
WIP on multiple homes and grading. oundation poured, did not see washout on site, no sign of dumped washout. No dirt leaving site, trackout on road inside site.
|
ESC17-00895
| General Inspection | 11/19/2018 | 11/19/2018 | 11/19/2018 12:29:22 PM | P | PASS |
|
|
WIP on multiple homes and grading. oundation poured, did not see washout on site, no sign of dumped washout. No dirt leaving site, trackout on road inside site.
|
ESC18-00987
| General Inspection | 11/19/2018 | 11/19/2018 | 11/19/2018 12:10:56 PM | P | PASS |
|
|
Home complete and landscaped. Sprinkler causing some runoff of wood mulch.
|
ESC17-01118
| Aging Inspection | 11/19/2018 | 11/19/2018 | 11/19/2018 11:50:36 AM | | PASS |
|
|
Two row homes complete and landscaped. WIP on 3rd home.
|
ESC17-01389
| General Inspection | 11/19/2018 | 11/19/2018 | 11/19/2018 11:25:33 AM | | PASS |
|
|
Inlet protection installed in new parking lot inlets, parking lot paved. Washout in good shape. No trackout or dust, site clean of garbage.
|
ESC17-01362
| General Inspection | 11/19/2018 | 11/19/2018 | 11/19/2018 10:24:54 AM | | PASS |
|
|
Clean site. Worker power washing front of building, no dirt in area and water is clean. Rear along greenbelt being landscaped. Wattles have been removed along sections, looks like they are being replaced as work progresses. Washout pan on site.
|