PDS Online
Making
Boise
the most livable city in the country.
Home
Permits
Search by Permit Number
How to search by permit number
Search by Address
Search by Customer Number
Search by Current Planning Number
Search in Project by Permit Number
Search by Project Name
Inspections
Search by Permit Number
Search by Request Date
Search by Company Name
Fees
Impact Fees Estimate Calculator
Other Searches
Search for Licensed Contractors
Search Parcel by Address
Search Historical Surveys
Reports
Daily Reports
Weekly Reports
Monthly Reports
Home
/
Inspections
/
Inspector Activity
Inspections for the day of:
Thursday, November 29, 2018
.
Number of inspections:
17
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Michael Zawacki
Title
EROSION INSPECTOR
Phone #
208-473-8333
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC17-00138
General Inspection
11/29/2018
11/29/2018
11/29/2018 2:38:06 PM
P
PASS
All work looks complete. Area landscaped and parking lot completed. No more materials stored on site.
ESC17-01304
Aging Inspection
11/29/2018
11/29/2018
11/29/2018 2:36:14 PM
CANC
ESC17-01304
DOC - Permit Finaled
11/29/2018
11/29/2018
11/29/2018 2:36:08 PM
P
PASS
ESC17-00985
General Inspection
11/29/2018
11/29/2018
11/29/2018 2:06:56 PM
PASS
Behind fence and gate. No dirt leaving site, some large stockpiles that are currently contained. Large buffer of common area between lot and road. Currently concrete forms installed.
ESC18-01160
General Inspection
11/28/2018
11/29/2018
11/29/2018 12:57:35 PM
P
PASS
Lot is bare and flat. No stockpiles or storage on site. Roofers currently working. nSidewalks are clean, no dirt leaving site.
ESC16-01560
General Inspection
11/29/2018
11/29/2018
11/29/2018 12:40:30 PM
PASS
Concrete truck on site using washout. Workers parking on lot, construction entrance installed, no trackout. A few fresh looking stockpiles. No dumped trash or ESC violations.
ESC16-01650
General Inspection
11/29/2018
11/29/2018
11/29/2018 12:20:10 PM
FAIL
Most lots are dirty with building waste. Trackout from west side of site. Concrete washout is failing and will need to be rebuilt or fixed before any more concrete work.
ESC15-01288
General Inspection
11/29/2018
11/29/2018
11/29/2018 12:01:13 PM
CANC
ESC15-01288
DOC - Permit Finaled
11/29/2018
11/29/2018
11/29/2018 12:01:07 PM
P
PASS
ESC13-01279
General Inspection
11/27/2018
11/29/2018
11/29/2018 11:39:19 AM
P
PASS
All work complete. Sent message to Kyle to pull inlet protection so permit can be closed.
ESC17-01414
BMP Violation
11/27/2018
11/29/2018
11/29/2018 11:19:04 AM
A
PASS
Alleys have been cleaned. Old washout cleaned and removed, new washout installed and clean. No activity at time of inspection.
ESC16-01561
General Inspection
11/27/2018
11/29/2018
11/29/2018 10:30:11 AM
A
PASS
Work along greenbelt and creek done, silt fence can be removed at any time.
Few units still under construction in middle of development, area is clean.
ESC17-00078
General Inspection
11/29/2018
11/29/2018
11/29/2018 10:07:11 AM
PART
One dump truck is driving in mud and tracking out. Washout in good condition.
ESC17-01191
Aging Inspection
11/29/2018
11/29/2018
11/29/2018 9:45:16 AM
CANC
ESC17-01191
DOC - Permit Finaled
11/29/2018
11/29/2018
11/29/2018 9:45:07 AM
P
PASS
ESC17-01472
Aging Inspection
11/29/2018
11/29/2018
11/29/2018 9:29:00 AM
PART
WIP on retatining wall. Exposed access is covered by reinforced poly. Some staining on road from shotcrete or mortar.
ESC17-00824
DOC - Permit Finaled
11/29/2018
11/29/2018
11/29/2018 9:18:07 AM
P
PASS