Inspections for the day of: Tuesday, May 1, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMichael Zawacki
TitleEROSION INSPECTOR
Phone #208-473-8333
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-00683 Aging Inspection5/1/20185/1/20185/1/2018 1:12:06 PM PASS
WIP. Site contained, no ESC issues.
ESC16-00905 Aging Inspection5/1/20185/1/20185/1/2018 1:02:01 PM FAIL
Construction complete and all crews left site. Old concrete washout was left on parcel to south. None of the drain inlets have had their witches hats removed.
ESC17-00111 General Inspection5/1/20185/1/20185/1/2018 12:52:16 PMPFAIL
Entire site is a mess and needs to be cleaned. Lots of scraps of lumber and drywall laying around, trash boxes are filled. Loose dirt all over site parking area and sidewalks. SOme plastic bags on ground in northwest corner.
Lumber is being store on drivw and is ok.
ESC18-00012 General Inspection5/1/20185/1/20185/1/2018 12:40:33 PMPPART
Two homes both framed. Concrete washout has been installed. Only saw permit displayed on one home. Lots of trash on site, needs to be cleaned.
ESC17-01157 General Inspection5/1/20185/1/20185/1/2018 12:23:42 PMPPASS
Area still exposed and roads under construction. Not much for BMPs but no issues. Majority of area is stockpiles of river rock.
ESC16-01512 General Inspection5/1/20185/1/20185/1/2018 12:21:56 PMPPASS
Site is mostly complete and undergoing stabalization. No ESC issues.
ESC17-00395 General Inspection5/1/20185/1/20185/1/2018 11:49:59 AMPPART
Outpak on site has been overfilled and is now buried, washout is being cleaned onto dirt. Lots of dirt on road through site. Trash is being cleaned, worker was walking around with can picking up loose trash when I arrived.
ESC17-00466 General Inspection5/1/20185/1/20185/1/2018 11:37:32 AMPPASS
WIP on multiple SFH. Site is clean and no trackout to road.
ESC17-01465 General Inspection5/1/20185/1/20185/1/2018 11:36:26 AMPPASS
Curb is installed. BMPs still on site and maintained. SWPPP is still being inspected and reports are in book. SWPPP & permit sign has been tipped over.
ESC18-00301 General Inspection5/1/20185/1/20185/1/2018 11:25:58 AMPPASS
no site prep requested...
Area has been rough graded. ESCP states that entrance is pre-existing. No work currently occuring. ESCP has no perimeter BMPs.
ESC17-01426 General Inspection5/1/20185/1/20185/1/2018 11:15:28 AMPPASS
Sidewalks, parking lot, curb & gutter completed. Most of irragation ditch has been piped, junctions still not complete. No dirt leaving site. No activity at time of inspection.
ESC18-00224 General Inspection5/1/20185/1/20185/1/2018 11:04:42 AMPPASS
No new activity. Two access roads onto site, neither has any type of stabalized rock or BMPs.