Inspections for the day of: Friday, May 18, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMichael Zawacki
TitleEROSION INSPECTOR
Phone #208-473-8333
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-00585 BMP Violation5/16/20185/18/20185/23/2018 11:41:59 AMPFAIL
Need to post ESC sign

Backfill stored adjacent to sidewalk is sediment runoff risk.
No permit sign, stock pile is still umprotected.
ESC16-00945 General Inspection5/18/20185/18/20185/21/2018 9:41:36 AM PASS
No trackout or runoff issues. Truck on site delivering top soil.
ESC15-00944 General Inspection5/18/20185/18/20185/18/2018 2:45:38 PM PASS
Rear is still disturbed and being used for church rehab storage. SIte free of ESC issues.
ESC16-01457 General Inspection5/18/20185/18/20185/18/2018 1:16:52 PM PART
Vegetation has grown in on most exposed areas. Some rilling and drain is draining lots of sand onto sidewalk.
ESC16-01472 General Inspection5/18/20185/18/20185/18/2018 1:14:03 PM PASS
Site contained, no run off issues.
Site will need lumber scrap pickup soon.
ESC18-00548 Tracking Control5/18/20185/18/20185/18/2018 12:59:38 PMPPEND
trackout complaint received.
Talked with RP Ed. Sweeper on site and will have his guys clean road and keep it clean. Will follow up.
ESC18-00109 Conference5/18/20185/18/20185/18/2018 12:41:17 PMPPEND
Lots of trackout leaving site. RP is aware and is on list of areas to fix.
ESC17-00791 Conference5/18/20185/18/20185/18/2018 12:40:44 PMPPASS
Wattle has been installed on slopes and is protecting site from sheet flow coming off of road. Wattle is installed end to end, not overlapping, chance water will push through seams and cause future rilling. Multiple gravel bags on site that haven't yet been installed.
ESC18-00177 Random Inspection5/18/20185/18/20185/18/2018 11:27:44 AMPPASS
WIP on grading. Old warm springs creek is protected by siltfence. Channel has been cut diverting creek into new creek bed, no work on filling old creek has begun.
ESC16-01253 General Inspection5/18/20185/18/20185/18/2018 10:44:42 AM PASS
Home complete, no runoff, weeds starting to cover property.
ESC17-00936 Random Inspection5/18/20185/18/20185/18/2018 10:24:22 AMPPASS
Curb and gutter now complete, site is contained. Lumber scraps will soon need to be picked up. SWPPP doesn't have an inspection since 4-9
ESC17-00791 Complaint Inspection5/18/20185/18/20185/18/2018 8:18:32 AMPPASS
RP Eric was on site with Syman company getting area repaired and BMPs installed. They will fix hillside and use sandbags to prevent sheet flow from road redirecting and draining on site. Some sediment was i neighbors back yard, there was no flooding of home. Will follow up to check progress of BMP installation.