Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-00592 Site Final5/23/20195/29/20195/31/2019 10:34:44 AMPPASS
ESC19-00260 General Inspection5/29/20195/29/20195/29/2019 3:19:16 PMPPASS
Excavator on site, no dirt has left site, BMPs in good shape. Will need to haul out back fill after basement is dug.
ESC19-00517 General Inspection5/29/20195/29/20195/29/2019 3:11:28 PMPPASS
Wattle on downhill slopw of acess road, larg natural buffer.
ESC19-00371 General Inspection5/29/20195/29/20195/29/2019 2:59:45 PMPPASS
Silt fence has been repaired where it wasn't trenched. DIversion added to road to deflect stormwater into vegetation. Silt fence added below road to catch any water flow, wattle added below to catch additional sediment and water as needed. Graded areas on hill have been tracked and wattle installed.
ESC17-00791 General Inspection5/29/20195/29/20195/29/2019 2:37:35 PMPFAIL
Blow out into neighbors yard. RP notified follow up scheduled.
ESC18-00845 General Inspection5/29/20195/29/20195/29/2019 2:29:51 PMPPASS
Sprinklers done, hasn't been hydroseeded.
ESC18-01576 General Inspection5/29/20195/29/20195/29/2019 1:06:37 PMPPASS
Soil absorbed all water. No runoff down hill.
ESC16-00353 General Inspection5/29/20195/29/20195/29/2019 12:55:17 PMPPASS
No major ESC issues, lots were able to hold the water.
ESC18-00498 General Inspection5/29/20195/29/20195/29/2019 12:42:58 PMPPEND
Met with RP.
Some sand on sidewalks, will add wattle. Access road to pond has rilling, thinking of adding riprap channel.
ESC16-00406 General Inspection5/29/20195/29/20195/29/2019 12:25:54 PMPPEND
Area around inlets needs sediment cleaned. Some runoff onto golf cart path. Specialty Supply on site with new wattles.
ESC18-00946 General Inspection5/29/20195/29/20195/29/2019 12:04:06 PMPPASS
No failures. Water conveyance system working, no new rilling. No sediment runoff, buildup behing wattles is getting high.
ESC17-00190 General Inspection5/29/20195/29/20195/29/2019 11:52:17 AMPPART
post rain inspection. Identify lots with most erosion/runoff so we can notify the developer/RP.
Message sent to RP. Storm system starting to fill with sediment. Witches hat between homes is full. Watlle has been run over a lot and not working so well. Some sediment run on on road and sidewalks.
ESC18-01719 General Inspection5/29/20195/29/20195/29/2019 11:26:00 AMPPASS
No runoff, only disturbed area is where foundation was.
ESC17-00954 General Inspection5/29/20195/29/20195/29/2019 11:07:38 AMPPASS
post rain inspection
ACHD sweeper working on Winsome.
Neighborhood snake bags need sediment cleaned and destroyed ones should be thrown away. First lot on left holding water. Talked to RPs about issues on their own lots.
No major issues with anything in neighborhood.
ESC18-01531 General Inspection5/29/20195/29/20195/29/2019 10:22:01 AMPPASS
post rain inspection
Syman crew on site replacing inlet protection.
Poly installed to catch water from roof and direct below home, silt fence catching flow. Silt fence with J-hook along front. Side lot is vacant and has some vegetation.
ESC18-01284 General Inspection5/29/20195/29/20195/29/2019 10:08:32 AMPPASS
Some building material stored in road. Front lot is pitrun. No ESC issues, no runoff going down hill.
ESC17-01287 General Inspection5/29/20195/29/20195/29/2019 10:02:30 AMPPASS
post rain inspection
No failures or washouts onto road. Crew on site working on forms for front steps. Pump driver dumped all the first bunch of mud on lower landing, big pile of concrete but is stable, no illicit washout.
ESC15-00857 General Inspection5/29/20195/29/20195/29/2019 9:51:23 AMPPASS
check on any hillside springs or drainage erosion on Bent Bow, 50 ft up from storm drain at Arrow Villa
No visible discharge, wet spots on road or sidewalk, or flows from hillside. No signs of road or sidewalk failure.
ESC18-01022 General Inspection5/29/20195/29/20195/29/2019 9:36:19 AMPPASS
No water made it to pond, all absorbed by growing hillside vegetation. No major issues at site.
ESC19-00556 General Inspection5/29/20195/29/20195/29/2019 9:34:25 AMPPASS
BMPs installed, no workers on site.
ESC18-00928 General Inspection5/29/20195/29/20195/29/2019 9:33:16 AMPPASS
Spoke with stucco contractor and PJ. Will get stucco washout pit dug before work. No ESC issues.
ESC18-00738 General Inspection5/29/20195/29/20195/29/2019 9:32:05 AMPPASS
Home completed and lot landscaped. Old silt fence still laying on ground and will need to be cleaned.
ESC18-00737 General Inspection5/29/20195/29/20195/29/2019 9:31:20 AMPPASS
Home exterior completed and lot landscaped. Steep area in front and side of home seeded.