Inspections for the day of: Thursday, June 18, 2020.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMichael Zawacki
TitleEROSION INSPECTOR
Phone #208-473-8333
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC19-01144 Aging Inspection6/18/20206/18/20206/18/2020 2:28:19 PM PASS
No dirt overtopped retaining wall. Some water followed wall into alley, did not cause any issues.
ESC15-01210 General Inspection6/18/20206/18/20206/18/2020 2:19:41 PM PASS
No issues at site.
ESC18-00164 General Inspection6/18/20206/18/20206/18/2020 2:19:23 PMPPASS
Water is flowing to onsite seepage beds. No erosion issues.
ESC19-00091 General Inspection6/18/20206/18/20206/18/2020 2:18:55 PM PASS
West end of back yard still needs landscaping. No issues.
ESC18-01576 General Inspection6/18/20206/18/20206/18/2020 2:18:22 PM PASS
Needs landscaping. Dog has invicible fence, didn't enter lot.
ESC19-00444 General Inspection6/18/20206/18/20206/18/2020 2:17:48 PM PASS
Landscapers on site.
ESC18-00179 General Inspection6/18/20206/18/20206/18/2020 11:24:14 AM PASS
WIP on multiple homes. No trash in creek. Area is clean. Some completed homes already have residents.
ESC19-01155 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:12:59 AMPPASS
ESC19-01148 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:12:52 AMPPASS
ESC19-01184 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:12:42 AMPPASS
ESC19-01176 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:12:32 AMPPASS
ESC19-01217 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:11:48 AMPPASS
ESC19-01238 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:11:02 AMPPASS
ESC19-01237 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:10:52 AMPPASS
ESC19-01225 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:10:41 AMPPASS
ESC19-01022 Aging Inspection6/18/20206/18/20206/18/2020 11:10:09 AM CANC
ESC19-00988 Aging Inspection6/18/20206/18/20206/18/2020 11:10:00 AM CANC
ESC19-01023 Aging Inspection6/18/20206/18/20206/18/2020 11:09:50 AM CANC
ESC19-01023 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:09:30 AMPPASS
ESC19-01022 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:09:23 AMPPASS
ESC19-00988 DOC - Permit Finaled6/18/20206/18/20206/18/2020 11:09:15 AMPPASS
ESC20-00145 General Inspection6/9/20206/18/20206/18/2020 10:59:04 AMPPEND
Site has dewatering well point and pump, not running at time of inspection. Outlet goes straight to creek. Will need to investigate as to if they submitted a plan and what their testing protocal is.
Section of creek along greenbelt is diverted to culvert and has road built over it. No issues with crossing, no plumes in creek flow at culvert exits.
ESC18-01504 General Inspection6/18/20206/18/20206/18/2020 10:37:14 AM PASS
No new activity.
ESC19-00371 General Inspection6/18/20206/18/20206/18/2020 10:36:18 AMPFAIL
Follow up on dewatering set up and turbidity
Turbidity reading.
East pipe on dam 73.8 NTU
Creek at start of flume 73.8 NTU
Creek at exit pipe at JH parking area. 180 NTU.
Dewatering water above flume 187 NTU
Dewatering water below bag 248 NTU.

While on site I adjusted the hose by placing it further into the bag. The water than flowed through more of bag. After about 10 minutes NTUs out of bag dropped to 231.
Water exeting site is still to high from background, results in failure and illicit discharge.
ESC19-00525 General Inspection6/18/20206/18/20206/18/2020 9:37:40 AM FAIL
Brundage Bone pumping and IMC on site. Washouts on site, not located where they can be used. One load of washout already dumped. Went and talked to foreman, he headed out to get a washout moved and mess cleaned.
Rest of site is clean and free from issues.