Inspections for the day of: Wednesday, June 26, 2019.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMichael Zawacki
TitleEROSION INSPECTOR
Phone #208-473-8333
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-00920 General Inspection6/26/20196/26/20196/26/2019 2:38:11 PM PASS
Foundation poured, washout used. Wattle is surrounding backfill. Rock entrance installed and trash box on site.
ESC19-00719 General Inspection6/26/20196/26/20196/26/2019 12:47:53 PMPPASS
Looked at home from driveway. No issues.
ESC19-00076 General Inspection6/26/20196/26/20196/26/2019 12:42:33 PMPPASS
Both entrances are stabalized, no entrances. Currently working on foundation, 3 washouts on site, some concrete spills on site. Perimeter controls in place, no blowing dust, no loose trash.
ESC17-01479 General Inspection6/26/20196/26/20196/26/2019 12:31:58 PMPPASS
WIP on last remaining homes. Some lumber scraps laying around. Road is clean, no issues at home sites.
ESC18-01182 Site Final6/26/20196/26/20196/26/2019 12:24:07 PMPNR
Lot not cleaned or landscaped.
ESC18-01172 Site Final6/26/20196/26/20196/26/2019 12:20:53 PMPPASS
ESC19-00473 General Inspection6/26/20196/26/20196/26/2019 12:18:43 PMPPASS
Work looks completed. Split rail fence back in place and access cleaned.
ESC18-01227 General Inspection6/26/20196/26/20196/26/2019 12:10:05 PMPPASS
Parking lot and all sidewalks and parking lot islands completed. No work on any of the lots.
ESC18-01390 General Inspection6/26/20196/26/20196/26/2019 12:01:04 PMPPART
Message sent to RP.
Silt fence along Roe is about destroyed, should be removed. Packing from lumber deliveries needs to be cleaned. Roofers throwing packaging t ground, needs to be cleaned end of day.
ESC19-00156 General Inspection6/26/20196/26/20196/26/2019 11:31:14 AMPPASS
No new activity at site.
ESC19-00376 Site Preparation6/25/20196/26/20196/26/2019 11:08:49 AMAFAIL
Sewer and water installed without ESC permit. 7 inlets around site not protected. Road has been saw cut but not patched, causing tracking down road, In areas where site is not below grade there is no perimeter controls. Multiple ways into site, one rock entrance made with round rocks.
Lined washout on site, permit is displayed but there is no info for RP. Large pile of tires has been dumped on site. Large exposed area with no dust control.
ESC18-00829 Aging Inspection6/26/20196/26/20196/26/2019 10:22:31 AM CANC
ESC18-00823 Aging Inspection6/26/20196/26/20196/26/2019 10:22:10 AM CANC
ESC18-00823 DOC - Permit Finaled6/26/20196/26/20196/26/2019 10:22:02 AMPPASS