Inspections for the day of: Tuesday, September 25, 2018.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMichael Zawacki
TitleEROSION INSPECTOR
Phone #208-473-8333
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-01140 General Inspection9/25/20189/25/20189/26/2018 2:19:46 PMPPASS
ESC17-00199 Aging Inspection9/25/20189/25/20189/26/2018 2:15:46 PM CANC
ESC18-00724 General Inspection9/25/20189/25/20189/26/2018 2:15:07 PMPPASS
Almost complete, site is stable.
ESC18-00598 General Inspection9/25/20189/25/20189/26/2018 2:04:08 PMPPASS
Curbing complete, acting as perimeter control. No trackout leaving site, some dust blowing off truck as it drove away. No dust from excavator on site.
ESC18-00548 General Inspection9/25/20189/25/20189/26/2018 1:59:39 PMPPASS
Few foundations in place, one home being framed. Lined washout on site, will need to be cleaned soon. Neighborhood BMPs in place.
ESC17-01362 General Inspection9/25/20189/25/20189/26/2018 12:54:42 PM PASS
Site is contained. Trash is all in central pile or dumpster. Mason saw has vacuum and is dust free. Stockpile has tackifier. All workers parking on street or workers parking lot, little vehicle traffic on site. Ecopans on site.
ESC18-01121 General Inspection9/25/20189/25/20189/25/2018 3:15:38 PMPPASS
Wellpoint in place, discharge is at 5.5 NTU.
ESC16-01472 General Inspection9/25/20189/25/20189/25/2018 12:40:32 PM PASS
All BMPs still in place. Gator guard on driveway has been ran over and flattened, still will work but needs to be watched. All work today is on interior.
ESC18-00079 Random Inspection9/25/20189/25/20189/25/2018 12:28:42 PMPPASS
Wall work complete, yard still needs to be landscaped.
ESC17-01196 General Inspection9/25/20189/25/20189/25/2018 12:22:37 PMPPASS
Hillside has weed growth and silt fence, no dirt leaving. Site is free from trash and road is clean.
ESC17-00838 General Inspection9/25/20189/25/20189/25/2018 12:14:26 PMPCANC
ESC16-00938 General Inspection9/25/20189/25/20189/25/2018 12:14:07 PM PASS
No runoff from hillside. Gator guards are still at bottom of hill above sidewalk.
ESC17-01196 General Inspection9/25/20189/25/20189/25/2018 12:13:09 PM CANC
Entry error
ESC18-01075 General Inspection9/25/20189/25/20189/25/2018 12:03:16 PMPPASS
All work complete, excavator still parked on lot. Sent message with RP to see if they are done.
ESC17-01220 General Inspection9/25/20189/25/20189/25/2018 11:26:08 AM PASS
Most exterior work completed. Jumptime is storing materials on sidewalk.
ESC18-01270 Random Inspection9/25/20189/25/20189/25/2018 10:55:35 AMPPART
No front perimeter control, small amount of dirt is on sidewalk , high potential for runoff when rain comes. Inlet is protected.
ESC17-00377 Aging Inspection9/25/20189/25/20189/25/2018 10:42:18 AM PASS
ESC17-00372 Aging Inspection9/25/20189/25/20189/25/2018 10:41:12 AM PASS
All work complete, building permit still open.
ESC16-00941 General Inspection9/25/20189/25/20189/25/2018 9:40:08 AM CANC
ESC16-00941 DOC - Permit Finaled9/25/20189/25/20189/25/2018 9:39:59 AMPPASS
ESC17-01104 General Inspection9/25/20189/25/20189/25/2018 9:00:29 AM PASS
No activity. Building permit still not picked up after changes.
ESC17-00378 Aging Inspection9/25/20189/25/20189/25/2018 8:47:40 AM CANC
ESC17-00378 DOC - Permit Finaled9/25/20189/25/20189/25/2018 8:47:37 AMPPASS
Expired, no activity in over year.