Information based on query as of Sunday, May 19, 2024.
Permit Information
Permit NumberBLD13-00181
StatusFinaled
Name PETRA INC
Site Address 5301 E WARM SPRINGS AVE
Project NameThe Terraces of Boise
Customer Number 
ePlanReviewNo
Description
The Terraces of Boise - Main Building Wings A and B - To construct a new 50,285 square foot, four story, wood framed independent living apartment building. This is a wing of a larger building, with wings separated by two-hour fire walls. This building is being constructed on top of an underground parking garage. The parking garage is separated from the above apartment building by a three-hour horizontal separation. This building is fully fire sprinklered. The sprinklers are used for story increase. First Floor: 14,885 sq. ft. with 11 apartments. Second Floor: 14,785 sq. ft. with 11 apartments. Third Floor: 11,865 sq. ft. with 9 apartments. Fourth Floor: 8,750 sq. ft. with 7 apartments. All floors contain mechanical/electrical and housekeeping areas. All construction per the approved plans and attached comment list. JCM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/8/20157/9/20157/9/2015PPASS
DetailsJim Storey
Kc Phone #: ###-####
BLD-Final6/12/20156/17/20156/17/2015APART
DetailsJim Storey
JC Phone #: ###-####
FIRE-Final Inspection6/12/20156/15/20156/15/2015APASS
DetailsThomas Walsh
Final FLS inspection of Wings A & B for TCO and final sign off.
NOTE: Both fire sprinklers and fire alarm systems have been singed off for this area.
Emergency lights and exit signs inspected - 90 minute test off of generator. All tested OK.
Fire extinguishers - OK
Fire lane sign installed.
Knox box installed and FD called to lock box with keys installed.
No other discrepancies pending - TCO approved by this office.

BLD-Final6/12/20156/15/20156/15/2015ACANC
DetailsJim Storey
Jesus Phone #: ###-####
BLD-Final6/12/20156/15/20156/15/2015ACANC
DetailsBob Archibald
JC// wing A & B Phone #: ###-####
BLD-Final6/11/20156/12/20156/12/2015PNR
DetailsTony Young
JC// wing A & B Phone #: ###-####,, conference only,, need trades 1st,, walk through only
BLD-Final6/9/20156/10/20156/10/2015PNR
DetailsJim Storey
John Phone #: ###-####
BLD-Final6/4/20156/4/20156/5/2015PPART
DetailsJim Storey
A, B, C Wings, mechanical support stairwell doors - JC Phone #: ###-#### smoke seals installed
BLD-Final6/2/20156/3/20156/3/2015APART
DetailsJim Storey
JC Phone #: ###-#### room doors all ok
BLD-Other5/19/20155/20/20155/20/2015APART
DetailsJim Storey
Fire collar // Phone #: ###-#### missing one 3 inch in ele rm west/ fire treat at overheaddoors
FIRE-Conference5/18/20155/19/20155/19/2015ADONE
DetailsThomas Walsh
Meeting to discuss upcoming fire alarm testing and subsequent occupancy (TCO) of wings A thru D.
BLD-Ceiling Grid Inspection4/22/20154/23/20154/23/2015APASS
DetailsJim Storey
1st and 2nd floor wind a b and c // JC Phone #: ###-####
BLD-Ceiling Grid Inspection3/24/20153/25/20153/25/2015APASS
DetailsJim Storey
3rd and 4th A,B, C possibly D // JC Phone #: ###-####
BLD-Ceiling Grid Inspection3/3/20153/3/20153/3/2015PPASS
DetailsJim Storey
JC Phone #: ###-#### 2nd floor corridor ceilling hard lid ok
BLD-Ceiling Grid Inspection2/26/20152/27/20152/27/2015APART
DetailsJim Storey
JC-2nd floor corridor ceiling for cover Phone #: ###-####west end ok to cover hard lids// east end remove ceilling duct in corridor wall needs isolated out/ fire tape / firespk out of lid/ firestop all ceilling penatrations.
BLD-Ceiling Grid Inspection1/20/20151/20/20151/20/2015PPART
DetailsJim Storey
JC-fire caulking for cover 4th floor wing B Phone #: ###-#### elavator rm storage rm no cover all rest ok to cover.
BLD-Ceiling Grid Inspection1/14/20151/15/20151/15/2015APASS
DetailsJim Storey
JC-shaft liner ceiling 4th floor stairwell B1 Phone #: ###-####
BLD-Other12/29/201412/29/201412/29/2014PPASS
DetailsJim Storey
JC-fire caulking soffits-1st floor wings B & A Phone #: ###-####
BLD-Other12/23/201412/24/201412/24/2014ANR
DetailsJim Storey
fire colcking first floor wing a // Jc Phone #: ###-####
BLD-Framing/Rough-in12/12/201412/15/201412/15/2014APASS
DetailsJim Storey
Gary Phone #: ###-#### 2nd floor a bld drops ok to cover
BLD-Energy code compliance12/9/201412/9/201412/9/2014PPASS
DetailsJim Storey
insulation third floor wing C and D// JC Phone #: ###-####coridor
BLD-Ceiling Grid Inspection12/9/201412/9/201412/9/2014PPASS
DetailsJim Storey
second floor wing D// JC Phone #: ###-####
BLD-Other11/28/201412/1/201412/1/2014AFAIL
DetailsJim Storey
closer to noon. fire colt. blockin// JC Phone #: ###-####
BLD-Ceiling Grid Inspection11/28/201411/28/201411/28/2014ANR
DetailsJim Storey
brett - ###-#### - first floor wing b
BLD-Ceiling Grid Inspection11/18/201411/19/201411/19/2014APART
DetailsJim Storey
jc Phone #: ###-####
BLD-Energy code compliance11/12/201411/13/201411/13/2014APASS
DetailsJim Storey
JC Phone #: ###-#### ok to insulate ceilling foamseal ok
BLD-Ceiling Grid Inspection11/7/201411/10/201411/10/2014PPASS
DetailsJim Storey
JC// 4th floor soffits Phone #: ###-####
BLD-Ceiling Grid Inspection11/5/201411/6/201411/6/2014APASS
DetailsJim Storey
JC-2 nd floor Phone #: ###-#### insulation and rc ok to cover 2nd floor/ sheer 1 st floor ok to cover a and b wing
BLD-Ceiling Grid Inspection11/4/201411/4/201411/4/2014PNR
DetailsJim Storey
JC Phone #: ###-####
BLD-Wall Bracing11/4/201411/4/201411/4/2014PPASS
DetailsJim Storey
JC Phone #: ###-####2nd floor interior ok
BLD-Wall cover10/30/201410/31/201410/31/2014APASS
DetailsJim Storey
JC Phone #: ###-####sheer nail pick up interior. 2nd and 3hird floor sheer ok
BLD-Energy code compliance10/30/201410/31/201410/31/2014ACANC
DetailsJim Storey
2nd floorJC Phone #: ###-####walls ok
BLD-Energy code compliance10/29/201410/30/201410/30/2014APART
DetailsJim Storey
JC Phone #: ###-####
BLD-Wall cover10/29/201410/30/201410/30/2014APART
DetailsJim Storey
JC Phone #: ###-####
BLD-Wall Bracing10/23/201410/24/201410/24/2014APASS
DetailsJim Storey
JC Phone #: ###-#### sheer wall osb ok 2nd floor
BLD-Energy code compliance10/16/201410/17/201410/17/2014APART
DetailsJim Storey
2nd fl B wing - Gary Phone #: ###-#### air seal for iecc exterior wall and floor ok.
BLD-Energy code compliance10/14/201410/15/201410/15/2014APASS
DetailsJim Storey
JC Phone #: ###-#### 3rd and fouth ok to cover/ ec insulation ok
BLD-Framing/Rough-in10/10/201410/13/201410/13/2014APART
DetailsJim Storey
Gary Phone #: ###-#### fourth floor tennent wall gyp need nailling tighter/ missing gyp at trusses.
BLD-Framing/Rough-in10/1/201410/2/201410/2/2014APASS
DetailsDave Hannah
Gary-3 fl corrider Phone #: ###-#### ok to cover upper 3rd
BLD-Framing/Rough-in9/22/20149/23/20149/23/2014APART
DetailsDave Hannah
4th floor B Wing corrider framing for cover // JC Phone #: ###-#### ok to sheetrock lids
BLD-Framing/Rough-in9/3/20149/4/20149/4/2014APART
DetailsJim Storey
J.C. Phone #: ###-#### exterior ok to cover/ truss repair/ pony wall for interior bearing/ starp mlb header to top plate/ strap post to beam roof popout.
BLD-Wall Bracing8/21/20148/21/20148/21/2014PPASS
DetailsJim Storey
Jason Phone #: ###-#### exterior ok/ interior ok/ ok to gyp coridor ceilling.
BLD-Other7/21/20147/21/20147/21/2014PPART
DetailsJim Storey
JC-fire blanket Phone #: ###-#### 1st floor ok
BLD-Wall Bracing7/21/20147/21/20147/21/2014PPASS
DetailsJim Storey
JC Phone #: ###-#### exterior ok for cover
FIRE-Conference3/19/20143/19/2014 P 
DetailsForrest France
JC at phone #: ###-####