Information based on query as of Sunday, May 19, 2024.
Permit Information
Permit NumberBLD14-01824
StatusFinaled
Name ESI
Site Address 525 E PARKCENTER BLVD
Project NameThe District at Parkcenter
Customer NumberBLD14-01818 FOR DRAWNGS
ePlanReviewYes
Description
(THE DISTRICT AT PARKCENTER - COTTAGE BUILDING C - #1) (2-8-15 PLAN MODIFICATION TO RE-DESIGN THE STRUCTURAL SYSTEM FROM THE FOUNDATION UP. REVISED STRUCTURAL DRAWINGS ARE FILED UNDER BLD14-01824 IN EPLANREVIEW.) (The drawings are filed under permit BLD14-01818 in ePlanReview) To construct a 9 dwelling unit two story apartment building with seven units having their own garage (i.e. 7 garages). Two dwelling units will not have garages. The total floor area of this building is about 12,487 square feet (8,080 square feet 1st story and 4,407 square feet 2nd story). All ground floor units within Cottage Building C - #1 are required to comply as Type B dwelling units. Two ground floor units within Cottage Building A - #2 are required to comply as Type A dwelling units. Work is to include interior nonbearing walls, 1-hr bearing walls, 1-hr roof-ceiling assemblies, 1-hr floor-ceiling assemblies, 1-hr dwelling unit separations, attic insulation, interior doors, exterior windows and doors, insulated exterior walls, “Hardi-board” exterior siding, exterior manufactured stone wainscot, composition roof shingles, common stairways within 1-hr corridors open to the outside, private interior stairways, garages, garage overhead doors, millwork, and finishes. Structural work includes concrete footings, concrete stem walls, concrete floor slabs on grade with thickened footings at interior bearing walls, wood floor trusses, wood roof trusses, wood columns, wood beams, and shear walls. Special inspection is required for soils, concrete, and wood. The designs for the roof trusses and floor trusses are deferred submittal items. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13R as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection1/31/20171/31/20171/31/2017PPASS
DetailsJim Page
Final life fire safety inspecion passed/complete
BLD-Final1/27/20171/30/20171/30/2017PPASS
DetailsJim Storey
cory Phone #: ###-####
BLD-Framing/Rough-in11/16/201611/16/201611/16/2016PPART
DetailsJim Storey
Owners unit framing Phone #: ###-#### Inspection requested via web by Corey Hockersmith ok to insulate and rock wall north
BLD-Final11/14/201611/15/201611/15/2016APART
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith temp ok listing door tags cleaned up/ attic insulation/ south unit pending
BLD-Final11/9/201611/14/201611/14/2016PDEFR
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Corey Hockersmith. Out of time
FIRE-Final Inspection11/9/201611/14/201611/14/2016APART
DetailsJim Page
Partial final life fire safety complete, final fire sprinkler inspection is complete, final fire alarm inspection is complete, fire extinguishers are in place with current inspection tags and knox box is in place. Building fire sub-panel reports to clubhouse main fire panel, life fire safety will be a partial pass until clubhouse is done and the inspection is finaled/passed.
BLD-Aging Inspection10/26/201610/26/201610/26/2016 PASS
DetailsJim Storey
wip
BLD-Wall cover6/13/20166/14/20166/14/2016PPASS
DetailsJim Storey
RC inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Framing/Rough-in6/7/20166/8/20166/8/2016PPASS
DetailsJim Storey
Framing inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Framing/Rough-in6/3/20166/7/20166/7/2016AFAIL
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith c/n isued
BLD-Wall Bracing3/25/20163/25/20163/25/2016PPASS
DetailsJim Sly
Roof and wall sheer inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Wall Bracing3/22/20163/22/20163/22/2016PNR
DetailsMike Jordan
Roof and wall sheer Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Foundation9/16/20159/18/20159/18/2015PPASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Footing9/11/20159/14/20159/14/2015APASS
DetailsJim Storey
Rebar and footing Phone #: ###-#### Inspection requested via web by Corey Hockersmith engery code ok under slab