Permit Information
Permit NumberBLD14-01828
StatusFinaled
Name ESI
Site Address 509 E PARKCENTER BLVD
Project NameThe District at Parkcenter
Customer NumberBLD14-01818 FOR DRAWNGS
ePlanReviewYes
Description
(THE DISTRICT AT PARKCENTER - INTOWN BUILDING A - #2) (The drawings are filed under permit BLD14-01818 in ePlanReview) (11-17-15 PLAN MODIFICATION TO RE-DESIGN THE STRUCTURAL SYSTEM FROM THE FOUNDATION UP. REVISED STRUCTURAL DRAWINGS ARE FILED UNDER BLD14-01828 IN EPLANREVIEW.) (8-25-15 PLAN MODIFICATION TO PROVIDE EXTERIOR EXPANDED POLYSTYRENE FOUNDATION INSULATION IN COMPLIANCE WITH SHALLOW FOUNDATION STANDARDS AT LOCATIONS WHERE THE BOTTOM OF THE FOOTINGS WILL BE LESS THAN 24 INCHES BELOW FINISHED GRADE. THE INTENT IS TO PREVENT FROST HEAVE.) To construct a three story apartment building having a total of 76 dwelling units (24 units 1st story, 26 units 2nd story, and 26 units 3rd story). The 1st story will have a 1,630 square foot storage area with 21 storage units. The interior court on the 1st story will be used for assembly purposes with the egress system passing through the building and sharing the egress system that serves the 1st story apartments. The 1-hr corridors will be enclosed and conditioned and the 1-hr exterior stairways on all stories will be open to the outside. The total floor area of this building is about 81,567 square feet (about 27,189 square feet each story). For building area reasons, this building is divided by a 2-hr fire wall, each side having about 13,550 square feet per story. All ground floor units are required to comply as Type B dwelling units. Two of those ground floor units are required to comply as Type A dwelling units. Because this building does not have an elevator, none of the units located on the 2nd and 3rd stories are regulated for accessibility to the disabled. Work is to include 2-hr fire walls, interior nonbearing walls, 1-hr bearing walls, 1-hr roof-ceiling assemblies, 1-hr floor-ceiling assemblies, 1-hr dwelling unit separations (fire partitions and horizontal assemblies), attic insulation, interior doors, exterior windows and doors, insulated exterior walls, “Hardi-board” exterior siding, exterior manufactured stone wainscot, composition roof shingles, membrane roof coverings for flat roofs, 1-hr common corridors, 1-hr common exterior stairways, draftstops in floors and attics, millwork, and finishes. Structural work includes concrete footings, concrete stem walls, concrete floor slabs on grade with thickened footings at interior bearing walls, wood floor trusses, wood roof trusses, wood columns, wood beams, and shear walls. Special inspection is required for soils, concrete, and wood. The designs for the roof trusses and floor trusses are deferred submittal items. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13R and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/22/20172/23/20172/23/2017APASS
DetailsJim Storey
Corey Phone #: ###-####
BLD-Final2/21/20172/22/20172/22/2017ACANC
DetailsDave Hannah
Corey Phone #: ###-####
BLD-Aging Inspection1/2/20171/2/20171/4/2017 NR
DetailsJim Storey
BLD-Aging Inspection10/31/201610/31/201610/31/2016 PASS
DetailsJim Storey
BLD-Final8/30/20168/31/20168/31/2016PPASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith
FIRE-Final Inspection8/31/20168/31/20168/31/2016PPASS
DetailsJim Page
Final fire sprinkler inspection complete, final fire sprinkler underground supply inspection complete, final fire alarm inspection complete, fire extinguishers are in place with current inspection tags, final life fire safety inspection passed/complete.
BLD-Conference8/29/20168/30/20168/30/2016APART
DetailsJim Storey
Corey Phone #: ###-#### wip
BLD-Aging Inspection8/17/20168/17/20168/17/2016 PASS
DetailsJim Storey
wip
BLD-Other8/2/20168/2/20168/2/2016APASS
DetailsJim Storey
Electrical penetration fire caulk in bathrooms Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Other7/22/20167/25/20167/25/2016APASS
DetailsJim Storey
Inspect fire extinguisher cabinet openings Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Ceiling Grid Inspection5/11/20165/11/20165/11/2016PPASS
DetailsJim Storey
Third floor bathroom ceilings Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Ceiling Grid Inspection5/9/20165/10/20165/10/2016APASS
DetailsJim Storey
Second floor bathroom ceiling inspections Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Ceiling Grid Inspection5/9/20165/9/20165/9/2016PFAIL
DetailsJim Storey
Second floor bathroom ceiling inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith /n postedc
BLD-Ceiling Grid Inspection5/4/20165/5/20165/5/2016APASS
DetailsJim Storey
First floor bathroom ceilings Phone #: ###-#### Inspection requested via web by Corey Hockersmith pending mech 1st floor
BLD-Ceiling Grid Inspection5/4/20165/4/20165/4/2016PCANC
DetailsJim Storey
First floor bathroom ceiling drops Phone #: ###-#### >> Inspection requested via web by Corey Hockersmith Inspection cancelled from web by: Corey Hockersmith
BLD-Conference4/11/20164/12/20164/12/2016PPASS
DetailsJim Storey
RC inspection third floor Phone #: ###-#### Inspection requested via web by Corey Hockersmith mech rm not done
BLD-Wall cover4/4/20164/5/20164/5/2016APASS
DetailsJim Storey
RC inspection second floor Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Wall cover3/28/20163/28/20163/28/2016PPART
DetailsMike Jordan
RC inspection first floor ceiling Phone #: ###-#### Inspection requested via web by Corey Hockersmith. Ok, areas above bathrooms not yet insulated.
BLD-Framing/Rough-in3/22/20163/22/20163/22/2016PPASS
DetailsMike Jordan
3rd floor framing Phone #: ###-#### Inspection requested via web by Corey Hockersmith. All previous coorection items have been resolved at 3rd. floor east, except for extending exterior portion of 2hr. wall.
BLD-Framing/Rough-in3/18/20163/21/20163/21/2016APART
DetailsJim Storey
Third floor framing inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith c/n posted
BLD-Framing/Rough-in3/18/20163/18/20163/18/2016PPASS
DetailsJim Storey
Second floor framing inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Framing/Rough-in3/16/20163/17/20163/17/2016PPASS
DetailsJim Storey
First floor east side Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Framing/Rough-in3/10/20163/14/20163/14/2016APART
DetailsJim Storey
First floor east side and third floor RC west side Phone #: ###-#### Inspection requested via web by Corey Hockersmith russ repairs/ king stud at plm east 1 st floor
BLD-Wall Bracing1/18/20161/19/20161/19/2016PPASS
DetailsJim Storey
Roof sheathing and strap nailing Phone #: ###-#### Inspection requested via web by Corey Hockersmith ok to cover
BLD-Wall Bracing1/5/20161/8/20161/8/2016APASS
DetailsJim Storey
Second and third floor sheer Phone #: ###-#### Inspection requested via web by Corey Hockersmith roof decking ok to cover.
BLD-Foundation6/10/20156/11/20156/11/2015APART
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Corey Hockersmith. Pending SI inspection.
BLD-Foundation6/8/20156/9/20156/9/2015APART
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith placed with si pending report
BLD-Foundation6/1/20156/2/20156/2/2015APART
DetailsJim Storey
Concrete at 10am. Please call if not able to make it before concrete. Phone #: ###-#### Inspection requested via web by Corey Hockersmith pending si
BLD-Footing5/27/20155/28/20155/28/2015ACANC
DetailsJim Storey
BLD-Footing5/27/20155/28/20155/27/2015ACANC
DetailsJim Storey
MTI scheduled for 1:30 PM, Concrete scheduled for 2:00 PM Phone #: ###-#### >> Inspection requested via web by Kevin Honeycutt Inspection cancelled from web by: Kevin Honeycutt
BLD-Footing5/21/20155/21/20155/21/2015APASS
DetailsJim Storey
si letter ok/ ft ok to place
BLD-Footing5/19/20155/20/20155/20/2015PPART
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith need si contract.
BLD-Footing5/18/20155/19/20155/19/2015PNR
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith need aproved plan on site/ need si contract