BLD-Final | 8/1/2017 | 8/2/2017 | 8/2/2017 | A | PASS |
Mike Jordan
|
|
|
Call half hour before // Chad or ###-#### Phone #: ###-####. All issues resolved. Ok for perm occ. No card to sign.
|
BLD-Final | 7/31/2017 | 8/1/2017 | 8/1/2017 | A | FAIL |
Mike Jordan
|
|
|
Call half hour before to meet /// Kyle Phone #: ###-####. Remove thumb turns from both exits and provide key locking hardware. Correction notice posted.
|
FIRE-Final Inspection | 7/26/2017 | 7/27/2017 | 7/27/2017 | A | PASS |
Troy Cobbley
|
|
|
life safety passed
|
BLD-Foundation | 6/21/2017 | 6/22/2017 | 6/22/2017 | A | PASS |
Mike Jordan
|
|
|
Art Phone #: ###-####. Reviewed engineer's approval for pressure treated wood and special inspection report for the post installed anchors. ok to skirt and install the code compliant ramp.
|
BLD-Other | 4/11/2017 | 4/11/2017 | 4/11/2017 | P | FAIL |
Mike Jordan
|
|
|
block & tie down: Phone #: ###-####. Provide the special inspection report for the concrete anchor sysem that has been isnstalled. Modualar building not installed per the approved plans. Building not set on steel piers as shown, but on wood. Iether place the modualr as shown or engineer of record to resubmit altermate method for approval. Correction notice was issued.
|