Permit Information
Permit NumberBLD17-00828
StatusFinaled
Name PARRY CONSTRUCTION
Site Address 10500 W BUSINESSPARK LN
Project NameCDMD Properties - Medical Off
Customer NumberCZC17-00092
ePlanReviewYes
Description
(CDMD PROPERTIES – OUTPATIENT MEDICAL CLINIC – NORTHEAST CORNER) (CZC17-00092) (9-22-17 PLAN MODIFICATION TO REMOVE THE DRINKING FOUNTAINS, ELIMINATE A STORAGE CLOSET TO EXPAND AN OFFICE, AND REMOVE A DOOR TO THE LAB. THE RECEPTION DESK MUST BE MAINTAINED ACCESSIBLE TO THE DISABLED AS ORIGINALLY APPROVED. BECAUSE THE OCCUPANT LOAD DOES NOT EXCEED 30, DRINKING FOUNTAINS ARE NOT REQUIRED.) This building does not have a fire sprinkler system. The building shell was constructed under permit BLD06-02311 but was never occupied. To complete a 1,576 square foot tenant space to be used as an outpatient medical treatment facility. Interior 1-hr fire-resistance-rated property line walls (i.e. 1 layers of 5/8” Type “X” gypsum board on each side of each wall – two walls total), 1-hr fire-resistance-rated roof-ceiling assembly used in lieu of parapets (i.e. 2 layers of 5/8” Type “X” gypsum board ceiling), and 1-hr fire-resistance-rated walls supporting the fire-rated roof structure (i.e. 1 layers of 5/8” Type “X” gypsum board on the inside) are required to be completed in compliance with the 2012 IBC. Additional work includes an interior concrete slab on grade, a new exterior storefront door with a new header above, 2 restrooms accessible to the disabled, interior nonbearing walls, interior doors, millwork, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/24/20181/25/20181/25/2018PPASS
DetailsMike Jordan
Please call ahead for access - Robert Phone #: ###-####. All isues resolved. ok for perm occ. No card on site to sign.
BLD-Final1/23/20181/23/20181/23/2018PFAIL
DetailsMike Jordan
please call before // Delbert Phone #: ###-####. Provide rated attic acces, remove the keyed hardware from the secondary door, lower breakroom cabinant and needs zoninf final.
FIRE-Final Inspection1/19/20181/22/20181/22/2018APASS
DetailsScott Arellano
Inspection passed. No sign off card on site.
BLD-Energy code compliance10/4/201710/5/201710/5/2017APASS
DetailsMike Jordan
Delbert Phone #: ###-####
BLD-Framing/Rough-in10/3/201710/3/201710/3/2017PPASS
DetailsMike Jordan
call when on way to meet // Delbert Phone #: ###-####
BLD-Other8/31/20178/31/20178/31/2017PDONE
DetailsMike Jordan
Ryan Phone #: ###-####. Verified install of vapor barrier prior to slab on grade being placed.