Information based on query as of Saturday, May 18, 2024.
Permit Information
Permit NumberBLD17-03407
StatusIssued
Name LIBERTY CONSTRUCTION CONTRACTORS LL
Site Address 10312 W CLAUDIA RD
Project NamePatten house move
Customer Number 
ePlanReviewNo
Description
House is an existing 1,461sq' structure moved from a slab-on-grade location and being placed on the site of a previously demolished home. Permit for a new foundation and floor to set existing home on. Project includes: removing non-bearing walls to make this a single family home, adding walls to create a laundry/mechanical room, redoing both bathrooms, redoing one kitchen (removing the other), and adding exterior stoops. All work per plans, notes, & local code. Separate electrical, plumbing & mechanical permits required. **JAB**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection12/11/201912/11/201912/12/2019 FAIL
DetailsTony Young
BLD-Aging Inspection12/10/201912/10/201912/11/2019 FAIL
DetailsTony Young
BLD-Wall Bracing7/29/20197/29/20197/29/2019PPART
DetailsTony Young
ok to side exterior rim areas after nailing the new rim to sill plate at 6" oc , ok to continue work
BLD-Conference7/29/20197/29/20197/29/2019PPART
DetailsTony Young
ok to side exterior rim areas after nailing the new rim to sill plate at 6" oc , ok to continue work,, told him to clear up the sewer fee due,, no further inspections untill fee is paid
Extend Permit 90/180 days7/29/20197/29/20197/29/2019PPASS
DetailsTony Young
ok to side exterior rim areas after nailing the new rim to sill plate at 6" oc , ok to continue work
BLD-Conference6/18/20196/21/20196/27/2019ADONE
DetailsTony Young
complaint of unsecure structure and squatters. Verify structure is secured against entry.// status review// cleaned up and secure
BLD-Conference6/17/20196/18/20196/18/2019AFAIL
DetailsTony Young
complaint of unsecure structure and squatters. Verify structure is secured against entry.// correction notice to secure the building and property,, notified on c/n that the permit will expire on July 31 if no required progress inspections are called in for..
BLD-Conference6/13/20196/13/20196/17/2019PFAIL
DetailsTony Young
complaint of unsecure structure and squatters. Verify structure is secured against entry.// still not secured,, need to post c/n next time
BLD-Conference6/6/20196/11/20196/13/2019APEND
DetailsTony Young
complaint of unsecure structure and squatters. Verify structure is secured against entry.
BLD-Conference6/6/20196/6/20196/6/2019AFAIL
DetailsTony Young
complaint of unsecure structure and squatters. Verify structure is secured against entry.
posted "do not occupy" red tag on building,, plywood is off of door openings,, also noted that 2 holes were cut through the rear walls on the front building,, construction fence is up
BLD-Conference6/4/20196/5/20196/6/2019ADEFR
DetailsTony Young
complaint of unsecure structure and squatters. Verify structure is secured against entry.,, out of time
BLD-Conference12/3/201812/7/201812/13/2018PPEND
DetailsTony Young
Status? no one around, no activity from last visit,, construction fence up in front
BLD-Conference11/20/201811/27/201812/3/2018PPEND
DetailsTony Young
Status?
BLD-Conference10/18/201810/19/201810/19/2018APEND
DetailsTony Young
check status// no one around,, house is sitting on foundation,, boarded up,, new apparent new activity
BLD-Conference10/17/201810/17/201810/18/2018PDEFR
DetailsTony Young
check status
BLD-Aging Inspection10/11/201810/11/201810/17/2018 PEND
DetailsTony Young
BLD-Aging Inspection10/10/201810/10/201810/11/2018 CANC
DetailsTony Young
BLD-Framing/Rough-in5/25/20185/29/20185/29/2018APART
DetailsTony Young
floor- Logan Phone #: ###-####,, floor frame ok,, work in progress
BLD-Foundation4/25/20184/25/20184/25/2018APART
DetailsTony Young
Logan Phone #: ###-####,, work in progress,, ok
BLD-Foundation4/24/20184/24/20184/25/2018PNR
DetailsTony Young
Logan Phone #: ###-####
BLD-Foundation4/23/20184/24/20184/24/2018ANR
DetailsTony Young
Logan Phone #: ###-####
BLD-Footing4/18/20184/19/20184/19/2018APASS
DetailsTony Young
plans on front of trailer- Logan Phone #: ###-####
BLD-Conference3/21/20183/22/20183/23/2018APASS
DetailsTony Young
status of fence/barrier
BLD-Conference3/22/20183/23/20183/23/2018APASS
DetailsTony Young
status of fence/barrier,, fence is up on the front of the property
BLD-Conference3/21/20183/21/20183/22/2018PNR
DetailsTony Young
status of fence/barrier
BLD-Conference3/15/20183/21/20183/21/2018AFAIL
DetailsTony Young
status of fence/barrier,, not up yet,, called Logan Patten and left a messege that this was the last day for the barrier 5 day notice,, he had called me on March 16th at 10:45 am and told me that they would have the fence up and should be calling for a footing inspection on the 19th,, nothing yet,, he also informed me that they are going to split the property to add more homes when they get central water to it.
BLD-Conference3/13/20183/15/20183/15/2018AFAIL
DetailsTony Young
status,, posted a 5 day notice to provide a protection barrier around property or raised house,, needs to be done by the end of the day March 21st, 2018
BLD-Conference3/12/20183/13/20183/13/2018AFAIL
DetailsTony Young
status/// needs barrior around property or homes,, 2nd home needs to be removed,, c/n posted on barrior,, code enforcement will be involved on removal of other structure
BLD-Conference3/7/20183/8/20183/8/2018APEND
DetailsTony Young
status,, posted a correction notice to provide a protection barrior/fence for raised homes
BLD-Conference1/11/20181/16/20181/17/2018PPEND
DetailsTony Young
Check status of project.,, footing trailer on site