Permit Information
Permit NumberBLD17-04590
StatusFinaled
Name DAVINCI STONE LLC
Site Address 11522 W FAIRVIEW AVE
Project NameDaVinci Stone Warehouse Add
Customer Number 
ePlanReviewYes
Description
(DAVINCI STONE – WAREHOUSE ADDITION) (DRH17-00255) The fire sprinkler system is used for building area increase, for fire area, and for fire flow. To construct a 7,161 square foot warehouse addition on the North end of an existing 10,010 square foot building. After the addition, this building will have a total floor area of about 17,171 square feet (18,078 square feet including the existing 907 square foot mezzanine). For the addition, work is to include concrete footings, concrete stem walls, concrete slab on grade, steel moment frames (beams and columns), steel columns, lateral bracing cables, steel roof purlins, steel roof panels, steel wall purlins, steel wall panels, an overhead door, and side-hinged swinging doors. A liner system with R-38 insulation, a vapor retarder installed on the warm in winter side of the insulation, and thermal spacers will be used to insulate the roof. The walls will be insulated with R-25 insulation with thermal break tape at the horizontal purlins and will have a vapor retarder installed on the warm in winter side of the insulation. Work to be done to the adjacent existing roof to support the added snow drift load includes additional steel purlins, purlin blocking, reinforcing steel plates welded to the top and/or bottom flange of existing steel beams, and additional bolts at existing beam splices. Special Inspection is required for concrete, steel (including bolting and welding), and anchors post-installed in hardened concrete. A new 8 foot tall masonry trash enclosure will be constructed. A separate permit is required for racks over 8 feet tall. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. A fire sprinkler system will be installed throughout this building (existing and new addition) in conjunction with this permit. This permit is intended to establish a Certificate of Occupancy for the entire building, the existing building and the building addition. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/21/20193/21/20193/21/2019PPASS
DetailsMike Jordan
Randy Phone #: ###-####
FIRE-Final Inspection1/15/20191/16/20191/16/2019APASS
DetailsTroy Cobbley
Life safety passed.

Randy Phone #: ###-####
FIRE-Final Inspection1/4/20191/4/20191/4/2019PFAIL
DetailsTroy Cobbley
Life safety will be ok to pass when the project related fire sprinkler permit is passed

Randy Phone #: ###-####
BLD-Final1/4/20191/4/20191/4/2019PNR
DetailsJim Sly
Randy Phone #: ###-####
Need Fir18-00609 sprinkler. Zoning and Fire life safety.
FIRE-Final Inspection1/4/20191/4/20191/4/2019PFAIL
DetailsTroy Cobbley
Need small documents and the project related fire sprinkler permit finaled.
FIRE-Conference11/27/201811/27/201811/27/2018PDONE
DetailsTroy Cobbley
Randy and I went over basic life safety requirements for his project.
BLD-Wall Bracing6/28/20186/29/20186/29/2018APASS
DetailsJim Sly
Jeff Phone #: ###-####
East 1/2 of Foundation Wall.....OK
BLD-Footing6/26/20186/27/20186/27/2018APART
DetailsJim Sly
Jeff Phone #: ###-####
East 1/2 of bldg.......OK. verified anchor bolts 24" long.
BLD-Foundation6/4/20186/5/20186/5/2018APART
DetailsJim Sly
Jeff Phone #: ###-####
No Special Inspection required. PART West 1/2 of Bldg. OK.
BLD-Footing5/31/20186/1/20186/1/2018PPASS
DetailsJim Sly
Jeff Phone #: ###-####