Information based on query as of Saturday, May 18, 2024.
Permit Information
Permit NumberBLD18-00377
StatusFinaled
Name CAMERON JAYO HOMES
Site Address 768 E ORION DR
Project NameLot 5 Block 9 Somerset No 5
Customer NumberCFH18-00023
ePlanReviewYes
Description
MODIFICATION - OVERALL TOPOGRAPHY HEIGHT ALTERED SLIGHTLY 10-15-18 **jab** WUI - HILLSIDE - Permit for the construction of a new 4258 sq. ft., two story (first story 2440 sq. ft., basement 1818 sq. ft.) single family dwelling with 5 bedrooms, 4.5 bathrooms, approximately 574 sq. ft. of covered patio/porch and a 880 sq. ft. attached garage per the approved plans, any notations, local codes & ordinances. A-1 zoning and setbacks per planning. **JAB**

A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

An erosion and sediment control site preparation inspection is required for this site. The site preparation inspection takes place after all required erosion and sediment control best management practices have been installed and BEFORE any earthwork takes place. Call 208-608-7070 to schedule an inspection.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/30/20203/31/20203/31/2020APASS
DetailsDave Hannah
Hello, please note that the inspector can gain access through the garage key pad the code is 5296 enter. Also the approved plans are in the top drawer on the right side of the kitchen range.
Thank You, Cameron Jayo Phone #: ###-#### Inspection requested via web by Cameron Jayo
DOC - Permit Finaled3/31/20203/31/20203/31/2020PPASS
DetailsDave Hannah
BLD-Aging Inspection11/29/201911/29/201912/2/2019 PEND
DetailsTony Young
BLD-Aging Inspection11/28/201911/28/201912/2/2019 PEND
DetailsTony Young
BLD-Energy code compliance7/12/20197/17/20197/17/2019PPASS
DetailsBrandon Shaw
Cameron Phone #: ###-####
BLD-Framing/Rough-in7/3/20197/8/20197/8/2019APART
DetailsDave Hannah
Camerpn Phone #: ###-#### c/n on site ok to insulate
BLD-Framing/Rough-in6/27/20197/2/20197/2/2019ANR
DetailsTony Young
Approved plans are by the Fireplace, please call with any questions.

Than You,

Cameron Jayo Phone #: ###-#### Inspection requested via web by Cameron Jayo
BLD-Framing/Rough-in6/26/20196/27/20196/27/2019PPART
DetailsTony Young
Approved plans are by the Fireplace, please call with any questions.

Than You,

Cameron Jayo Phone #: ###-#### Inspection requested via web by Cameron Jayo,, conf walk through only
BLD-Other5/9/20195/10/20195/10/2019APASS
DetailsTony Young
Cameron- fire rock on faucet Phone #: ###-####
BLD-Wall Bracing4/23/20194/24/20194/24/2019PPASS
DetailsTony Young
Inspection requested via web by Cameron Jayo
BLD-Wall Bracing4/22/20194/23/20194/23/2019ANR
DetailsTony Young
Approved plans are by the fireplace. Thanks Inspection requested via web by Cameron Jayo,, correction notice posted,, need to nail per plan
BLD-Wall Bracing4/16/20194/18/20194/17/2019ACANC
DetailsTony Young
Approved plans are by the Fireplace. Thank You Phone #: ###-#### >> Inspection requested via web by Cameron Jayo Inspection cancelled from web by: Cameron Jayo
BLD-Aging Inspection3/29/20193/29/20193/29/2019 PEND
DetailsTony Young
BLD-Aging Inspection3/28/20193/28/20193/29/2019 PEND
DetailsTony Young
BLD-Other12/19/201812/19/201812/19/2018PPART
DetailsJim Storey
1 please- Bill Phone #: ###-#### vapor barrior ok for under slab// no exterior wall water barrior befor back fil
BLD-Foundation11/13/201811/14/201811/14/2018APASS
DetailsTony Young
Bill Phone #: ###-####,, basement and retaining walls ok
BLD-Footing11/13/201811/13/201811/13/2018PPASS
DetailsTony Young
Bill Phone #: ###-####,, slab footings,, walls ok also
BLD-Footing11/1/201811/2/201811/2/2018APASS
DetailsTony Young
Bill ###-####, late am
BLD-Footing11/1/201811/1/201811/1/2018PNR
DetailsTony Young
Bill ###-####,,