Permit Information
Permit NumberBLD18-01817
StatusFinaled
Name WRIGHT BROTHERS THE BLDG CO EAGLE
Site Address 176 S CAPITOL BLVD
Project NameBusiness Interiors of Idaho
Customer Number 
ePlanReviewYes
Description
(BUSINESS INTERIORS OF IDAHO – 2nd FLOOR) (Note: Architect has requested a change to the type of construction from a type IIB to type VB building see letter attached.) Permit is to remodel an existing 6,300 sq. ft. business space. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames, removal of select plumbing fixtures, removal of select millwork, construction of interior non-bearing walls to create (6) offices, a break area, (2) conference rooms, accessible restrooms and open office areas, select new door/door frames, a new stairway leading to a 100 sq. ft. mezzanine, millwork, new gypsum and suspended acoustic ceiling, new light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is Not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/16/20189/17/20189/17/2018APASS
DetailsDave Hannah
Building final Business Interiors. Super working on exterior make sure to contact number above upon arrival. Phone #: ###-#### Inspection requested via web by Devan Hardwick
FIRE-Final Inspection9/13/20189/14/20189/14/2018APASS
DetailsMike Jordan
Re-Inspection of door hardware on sliding glass door and swing door to ensure no locking mechanisms.
Please contact Devan Hardwick prior to arrival at number provided. Phone #: ###-#### Inspection requested via web by Devan Hardwick. All issues resolved. Ok for final.
FIRE-Final Inspection9/12/20189/13/20189/13/2018PFAIL
DetailsMike Jordan
Final Inspection for fire/life/safety
SEE DESCRIPTION BY JAVIER GUZMAN: BUILDING IS INTENDED NON FIRE-SPRINKLERED. MINOR CHANGES MADE, PROJECT FLOOR IS OPEN PLENUM, SMOKE DETECTORS UPDATED, OTHERWISE SYSTEM REMAINS THE SAME.
Please contact Devan Hardwick prior to arrival for parking. Phone #: ###-#### Inspection requested via web by Devan Hardwick. Remove the thumb turn and key locking hardware from the glass sliding doors upstairs. Remove the ke locking hardware or provide single action lever hardware from the side hung glass door. Noted that new smoke detectors installed are of the same model. No fire alarm permit will be required.
BLD-Ceiling Grid Inspection8/16/20188/17/20188/17/2018ADONE
DetailsDave Hannah
Devin-above grid Phone #: ###-####
BLD-Ceiling Grid Inspection8/16/20188/17/20188/17/2018APASS
DetailsDave Hannah
Devin Phone #: ###-####
BLD-Framing/Rough-in6/25/20186/25/20186/25/2018PPASS
DetailsJim Sly
Devin Phone #: ###-####