BLD-Final | 3/29/2019 | 4/1/2019 | 4/1/2019 | A | PASS |
Jim Sly
|
|
|
Justin Phone #: ###-#### Blower door test 4.7
|
DOC - Permit Finaled | 4/1/2019 | 4/1/2019 | 4/1/2019 | P | PASS |
Jim Sly
|
|
|
|
BLD-Final | 3/27/2019 | 3/27/2019 | 3/27/2019 | P | FAIL |
Jim Sly
|
|
|
Justin Phone #: ###-#### C/N....blower door and holes at Garage ceiling near furnace.....both units.
|
BLD-Energy code compliance | 1/29/2019 | 1/30/2019 | 1/30/2019 | A | PASS |
Jim Sly
|
|
|
Justin Phone #: ###-####
|
BLD-Framing/Rough-in | 1/28/2019 | 1/29/2019 | 1/29/2019 | A | NR |
Jim Storey
|
|
|
Justin Phone #: ###-####
|
BLD-Framing/Rough-in | 1/25/2019 | 1/28/2019 | 1/28/2019 | A | FAIL |
Brandon Shaw
|
|
|
Corrections not all done... Fire caulk, not foam seal penetrations in fire wall, both sides... A6.1, details 3 and 4 not followed, need mineral wool or letter from Engineer of record approving as built...
|
BLD-Framing/Rough-in | 1/16/2019 | 1/17/2019 | 1/17/2019 | A | FAIL |
Brandon Shaw
|
|
|
Fire caulk all penetrations in fire wall... 3 ply truss to bear down to foundation... Provide strap at break in double top plate... Provide truss Engineering... As per pg A6.1, detail 4- install mineral wool at fire wall... See red paint...
|
BLD-Framing/Rough-in | 1/11/2019 | 1/14/2019 | 1/14/2019 | A | FAIL |
Brandon Shaw
|
|
|
No plumbing permit showing for this address... No rough-in approved...
|