Permit Information
Permit NumberBLD18-02450
StatusFinaled
Name CLC INC DBA IDAHO PIZZA COMPANY
Site Address 7444 W FAIRVIEW AVE
Project NameIdaho Pizza TI - Westgate
Customer Number 
ePlanReviewYes
Description
(IDAHO PIZZA TI - WESTGATE SHOPPING CENTER) Permit for a tenant improvement in an existing 7,322 sq ft tenant space for a new pizza restaurant in the Westgate Shopping Center. This space was previously occupied by Hastings. Shell work and tenant demising wall constructed under BLD17-03244 and BLD18-01089. Work to include: construction of new interior non-bearing partition walls; kitchen and equipment; structural reinforcing of existing roof for new oven hood and make-up air unit; fully accessible restrooms; plumbing, electrical, and mechanical work; interior finishes in compliance with Ch. 8 of the 2015 IBC. This building is fully Fire Sprinklered for area increase with an approved Fire Alarm system. Any alterations or modifications to the building’s Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 and NFPA 72 as regulated by the Boise Fire Department. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/6/201812/7/201812/7/2018PPASS
DetailsJim Sly
as early as you can- Candy Phone #: ###-####
OK for Perm Occ.
FIRE-Final Inspection12/6/201812/7/201812/7/2018APASS
DetailsTroy Cobbley
Life safety passed. Candy removed the walls and will resubmit when they are installed again.


Candy Phone #: ###-####
BLD-Final12/4/201812/5/201812/5/2018ANR
DetailsJim Sly
for temp // candy Phone #: ###-####
Need Fire approval.
FIRE-Final Inspection12/4/201812/4/201812/4/2018PFAIL
DetailsTroy Cobbley
No small documents on site, need a fire alarm permit for the interconnection of the hood suppression system and the existing fire alarm system as per the approved plans ( E sheet), need hood suppression system tested and permit finaled, need occupant load sign, need panic hardware as per plans on both of the east side exit doors, need plan modifications showing the accordian walls that are being installed for exiting to be approved including exit signs/emergency lights/hardware/modified occupant loads...ect., need sprinkler modifications now due to the new accordian walls. If there are items on the approval notes that are additional to these comments they will need addressed as well. It looks like the exit signs/emergency ligths and fire extinguishers are ok.


as late as possible // candy Phone #: ###-####
BLD-Framing/Rough-in10/25/201810/25/201810/25/2018PPASS
DetailsJim Sly
Candy Phone #: ###-####