Permit Information
Permit NumberBLD18-02873
StatusFinaled
Name CLEAR CREEK CONSTRUCTION LLC
Site Address 350 N MILWAUKEE ST Unit: 1147
Project NameBTS - #1147 Wetzel's Pretzels
Customer NumberBLD18-03812 EARLY START
ePlanReviewYes
Description
(WETZEL’S PRETZELS – BOISE TOWN SQUARE – SPACE 1147) Permit is to remodel an existing 940 sq. ft. tenant space for food business use. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames, removal of storefront gazing and roll-up gate, removal of select suspended acoustic ceiling, removal od=f select light fixtures, construction of interior non-bearing walls to create a food storage and kitchen area, new kitchen equipment, counters, a new 2’ x 2’ concrete pad, select new suspended acoustic and gypsum ceiling, select new light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. Note: This facility includes an engineered smoke control system throughout the mall, any modifications to smoke and/or fire dampers shall be reviewed and approved by the mall engineer, the smoke evacuation system shall remain operational as originally installed under the 1985 UBC. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/3/20191/4/20191/4/2019APASS
DetailsMike Jordan
Marvin Phone #: ###-####. Ok for perm occ.
BLD-Final12/24/201812/24/201812/24/2018ACANC
DetailsJim Sly
Marvin 208 573 6361
Will call for final when Mike returns........
BLD-Final12/20/201812/21/201812/24/2018APEND
DetailsJim Sly
Marvin Phone #: ###-####
Re-scheduled for12/24/18........
BLD-Final12/12/201812/14/201812/14/2018PPART
DetailsMike Jordan
Marvin Phone #: ###-####. OK for temp oc. Pending mech. and locking hardware at swinging door.
FIRE-Final Inspection12/12/201812/14/201812/14/2018APASS
DetailsTroy Cobbley
life safety passed

Marvin Phone #: ###-####
BLD-Framing/Rough-in12/12/201812/13/201812/13/2018APASS
DetailsBrandon Shaw
Ceiling grid
BLD-Framing/Rough-in12/5/201812/6/201812/6/2018APART
DetailsJim Sly
Marvin Phone #: ###-####
Hard lid.......OK
BLD-Framing/Rough-in11/26/201811/26/201811/27/2018PPASS
DetailsMike Jordan
Marin Phone #: ###-####