Permit Information
Permit NumberBLD18-03157
StatusFinaled
Name STRAIGHT LINE BUILDING SOLUTIONS LL
Site Address 5925 W VANDAL LN
Project NameCatapult
Customer Number 
ePlanReviewYes
Description
**(CATAPULT)** //Plan modification to add a 1-hour rated fire pump room for the existing unprotected fire pump equipment in the warehouse area, to include 1-hour rated walls, 1-hour rated ceiling, ¾ hour rated doors. 11-14-2018 JG // Permit is to remodel an existing 43,700 sq. ft. warehouse/office tenant space by dividing it into two separate tenant spaces, this tenant space is to be 25,845 sq. ft. and the remaining 17,855 sq. ft. is to be an unoccupied tenant space created under BLD18-03595. Approval is contingent upon adhering to the approved plans on file and plan review report. Work to include: construction of select interior nonbearing wall to demise tenant spaces, new walls to create a printer room, a conference room, an accessible restroom and open office area, select new door/door frames, select new suspended acoustic and gypsum ceiling, select new light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/10/20191/11/20191/11/2019PPASS
DetailsMike Jordan
Call half hour before // Sean Phone #: ###-####. Ok for perm occ.
FIRE-Final Inspection1/10/20191/11/20191/11/2019APASS
DetailsTroy Cobbley
Life safety passed. Building inspector will verify the exit sign/emergency light is repaired and the other stand alone emergency light is repaired or removed.

Call half hour before // Sean Phone #: ###-####
BLD-Final1/3/20191/4/20191/4/2019ANR
DetailsMike Jordan
Shawn Phone #: ###-####
FIRE-Conference1/4/20191/4/20191/4/2019PDONE
DetailsTroy Cobbley
I went over general life safety requirements with the general contractor and discussed the possible need for a duct smoke detector and separate FIR permit for the new 10 ton HVAC unit serving the new areas.
BLD-Ceiling Grid Inspection12/19/201812/19/201812/19/2018PPASS
DetailsMike Jordan
Shawn Phone #: ###-####
BLD-Framing/Rough-in11/30/201812/3/201812/3/2018APASS
DetailsJim Sly
Sean Phone #: ###-####
BLD-Framing/Rough-in11/9/201811/13/201811/13/2018APASS
DetailsMike Jordan
Sharn Phone #: ###-####. Inteior steel stud framed walls ok.
BLD-Framing/Rough-in11/6/201811/7/201811/7/2018APASS
DetailsMike Jordan
demising walls- Tom Phone #: ###-####. Demissing wall only ok.