Permit Information
Permit NumberBLD18-04267
StatusFinaled
Name SYRINGA CONSTRUCTION OF IDAHO LLC
Site Address 410 W ADA ST
Project Name 
Customer NumberDEMO BLD18-03434
ePlanReviewNo
Description
***PLAN MODIFICATION 7-2/19 - Modifying the Storage Space (588 sq ft) over the detached Garage into Living Space; adding a sink, toilet, washer and dryer connections to the Living Space over the detached Garage. NO ADU IS APPROVED. NO TUB, SHOWER OR RANGE IS ALLOWED.*** PLAN MOD - 2/6 Adding a 6"x24" frost wall at to the front porch area on the Foundation Plan. See revised Foundation Plan *** (HERS RATING: EXPEDITED REVIEW) (NO ADU IS PERMITTED UNDER THIS PERMIT) Permit for the construction of a new 3,763 sq. ft., two story (first story 1,961 sq. ft., second story 884 sq. ft., below grade 916 sq. ft.) single family dwelling with 4 bedrooms, 3 and 2 half bathrooms, approximately 417 sq. ft. of covered patio/porch and a 832 sq. ft. attached garage per the approved plans and any notations. R-1CH zoning and setbacks per planning. Engineering has been provided for beams, headers and Basement wall designs, ***BJM***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/16/20198/16/20198/16/2019PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Steve Hanson
DOC - Permit Finaled8/16/20198/16/20198/16/2019PPASS
DetailsBrandon Shaw
BLD-Final8/15/20198/16/20198/16/2019ANR
DetailsBrandon Shaw
House should be open. Please call with any questions.

Thanks! Phone #: ###-#### Inspection requested via web by Steve Hanson
BLD-Energy code compliance7/22/20197/22/20197/22/2019PPASS
DetailsBrandon Shaw
Corrections SAT...
BLD-Energy code compliance7/18/20197/19/20197/19/2019AFAIL
DetailsJim Storey
Hi,
Need an energy inspection for the storage area above detached garage.
Thank you Phone #: ###-#### Inspection requested via web by Steve Hanson missing vappor barrior on walls with attic exposer.
BLD-Energy code compliance7/16/20197/17/20197/17/2019APART
DetailsBrandon Shaw
Garage only...
BLD-Framing/Rough-in7/15/20197/15/20197/15/2019PPASS
DetailsBrandon Shaw
Living space above garage, framing rough-in...
BLD-Framing/Rough-in6/25/20196/26/20196/26/2019AFAIL
DetailsTony Young
framing reinspection and energy for garage. Power and vent have been removed from area above garage. Phone #: ###-#### Inspection requested via web by Steve Hanson/// need review set of plans from the city to reflect as built on garage floor plan with fixtures as well as electrical,, needs re-inspection on trades after as built approvals from city review.
BLD-Framing/Rough-in6/18/20196/18/20196/18/2019PFAIL
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Steve Hanson,, SWO issued on upper garage area,, components are in for an Accessory dwelling unit (ADU), electrical, plumbing, etc, ,,remove or get approval,, lower area of garage needs fur downs if allowed to keep.. also need to verify mechanical has been looked at.. need to justify how the 1 hour seperation will be made if occupancy seperation is allowed.. ok to insulate lower area in garage if desired
BLD-Framing/Rough-in6/4/20196/5/20196/5/2019PNR
DetailsTony Young
We need a framing/rough-in inspection for the detached garage please.
Thank you Phone #: ###-#### Inspection requested via web by Steve Hanson,,, needs trades 1st
BLD-Framing/Rough-in5/17/20195/17/20195/17/2019PPASS
DetailsBrandon Shaw
Correctiions SAT...
BLD-Energy code compliance5/16/20195/16/20195/17/2019PPEND
DetailsBrandon Shaw
No ceiling cover- need Truss Engineering
BLD-Framing/Rough-in5/10/20195/13/20195/13/2019APART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Steve Hanson,, correction notice posted,, house only
BLD-Wall Bracing4/30/20194/30/20194/30/2019PPASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Steve Hanson,, garage ok
BLD-Wall Bracing4/16/20194/16/20194/16/2019PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Steve Hanson
BLD-Foundation3/26/20193/26/20193/26/2019APART
DetailsTony Young
Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro,, garage walls,, work in progress
BLD-Footing3/22/20193/22/20193/22/2019APART
DetailsTony Young
As late as possible Phone #: 2088708888 >> Inspection requested via mobile web by Wes,, garage footings ok
BLD-Foundation3/8/20193/8/20193/8/2019APASS
DetailsDave Hannah
As late as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro
BLD-Footing3/7/20193/7/20193/7/2019PPART
DetailsTony Young
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro ,, grade footings on north side,, will need compaction reports and means to have the footing below grade on the west side
BLD-Foundation2/18/20192/19/20192/19/2019APART
DetailsTony Young
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro.. basement wall,, work in progress,, also planter
BLD-Footing2/6/20192/6/20192/6/2019PPART
DetailsTony Young
Wes Phone #: ###-####,, basement footing,, work in progress,, needs to be 12" thick