Permit Information
Permit NumberBLD19-00476
StatusFinaled
Name CARROLL CONSTRUCTION
Site Address 407 W BANNOCK ST Unit: 10
Project NameVanilla Suite #10
Customer NumberBLD19-00475 & BLD19-00477
ePlanReviewYes
Description
(VANILLA – RADAR BLDG - BASEMENT SUITE #10) NO OCCUPANCY ALLOWED UNDER THIS PERMIT. TENANT SHALL APPLY FOR CERTIFICATE OF OCCUPANCY PRIOR TO OCCUPYING THE SPACE. (An Interior non-structural demo permit was issued under BLD19-00600) Permit is to remodel an existing 946 sq. ft. business space. Approval is contingent upon adhering to the approved plans on file and plan review report. Work to include: removal of interior stairs and infill floor opening, removal of interior bearing and nonbearing walls, removal of interior nonbearing masonry walls, removal of exterior and interior door/door frames, removal of chimney and infill ceiling opening , removal of exterior windows, removal of wood floor and replace with concrete slab, removal of gypsum ceiling, removal of millwork, removal of plumbing fixtures, construction of new exterior concrete basement front entry stairs/landings and a retaining wall with guards and handrails, construction of interior bearing and non-bearing walls to create an office, a conference room, a reception area, (3) open office area and an accessible restroom, new interior furred at the exterior envelope walls with insulation, new exterior windows, new door/door frames, new exterior storefront entry door, new wall infill at old exterior wall door opening, millwork, new gypsum ceiling, light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. Note: special inspection required, see 310 form. Note 2: design engineering under BLD19-00475. This building is Not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/10/20197/11/20197/11/2019APASS
DetailsDave Hannah
Armando Phone #: ###-####
BLD-Final7/10/20197/11/20197/11/2019ACANC
DetailsDave Hannah
Armando Phone #: ###-####-needed fire life safety instead of bldg final
FIRE-Final Inspection7/10/20197/10/20197/10/2019PPASS
DetailsJim Page
No fire sprinklers, no fire alarms, fire extinguisher is placed with a current inspection tag. Final life fire safety inspection for area of work complete, as stated in job description, no occupancy allowed under this permit.

Armando Phone #: ###-####
BLD-Framing/Rough-in4/11/20194/12/20194/12/2019APASS
DetailsDave Hannah
Ken Phone #: ###-####
BLD-Conference3/22/20193/25/20193/25/2019ADONE
DetailsDave Hannah
Ken Phone #: ###-####