Permit Information
Permit NumberBLD19-00483
StatusFinaled
Name PRIMARY CONSTRUCTION INC
Site Address 3724 S ECKERT RD Unit: 111
Project NameThe STIL Gelato & Bistro
Customer Number 
ePlanReviewYes
Description
(THE STIL GELATO & BISTRO) **PLAN MOD ADJUSTED DEMISING WALL TO AS-BUILT ADDED FALSE WALLS FOR ELECTRICAL PANEL AND BEHIND SERVICE AREA EQUIPMENT.** Permit for the first tenant improvements to a 1500 sq. ft. shell space built out under BLD14-03081. This building is fire sprinkled for story and height increase. This tenant space is located on the first story of a three story building seperated from the residential stories above by a one hour horizontal assembly. Work to include: Saw cut floor for below slab plumbing work. New work to include: non-load bearing interior walls, doors, door frames, kitchen with hand sink, 3-compartment sink, kegerator, bar sink, accessible bathroom and drinking fountain are exisitng and shared with adjacent vanilla space. New over head door and patio seating see DRH19-00024. New electrical work, mechanical work, and plumbing work which each require a seperate permit. Interior finishes shall comply with Ch. 8 of the 2015 IBC. This building is fire sprinkled and has an approved fire alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **MDH**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/20/20196/21/20196/21/2019APASS
DetailsJim Storey
Plumbing backflow cert passed and all other inspections complete. Looking for final sign-off for full Occupancy Phone #: ###-#### Inspection requested via web by Ryan Wilhelm
BLD-Final6/12/20196/12/20196/12/2019APART
DetailsBrandon Shaw
See PLM19-01175- need back flow cert...
FIRE-Final Inspection6/6/20196/7/20196/7/2019APASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguishers will be placed in discussed locations and have current inspection tags. Final life fire safety inspection for area of work complete.

To coincide with Fire Alarm final for Johnson Controls/TYCO. Had a miscommunication in scheduling previously. Phone #: ###-#### Inspection requested via web by Ryan Wilhelm
FIRE-Final Inspection6/5/20196/6/20196/6/2019AFAIL
DetailsJim Page
Fire alarm contractor did not request an inspection, project associated FIR permits need to be finaled before life fire safety can be performed.

To coincide with Alarm test scheduled by Johnson Controls/TYCO. Phone #: ###-#### Inspection requested via web by Ryan Wilhelm
BLD-Ceiling Grid Inspection5/12/20195/13/20195/13/2019APEND
DetailsBrandon Shaw
OK to cover, pending Mech rough-in...
BLD-Framing/Rough-in4/8/20194/9/20194/9/2019PPASS
DetailsBrandon Shaw
OK to cover...
BLD-Framing/Rough-in4/8/20194/8/20194/8/2019PNR
DetailsBrandon Shaw
Plumbing/Electrical rough-in in AM Phone #: ###-#### Inspection requested via web by Ryan Wilhelm