Permit Information
Permit NumberBLD19-00699
StatusFinaled
Name RACHAEL MOORE
Site Address 9581 W FRANKLIN RD
Project NameMoore Residence - 9581
Customer NumberESC19-00249
ePlanReviewYes
Description
**PRESCRIPTIVE ENERGY REQUIREMENTS** Permit for the construction of a new 2067 sq. ft., one story single family dwelling with 2 bedrooms, 2 bathrooms, approximately 247 sq. ft. of covered patio/porch and a 664 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/4/20206/5/20206/5/2020PPASS
DetailsMike Jordan
screened // Rachael Phone #: ###-####
DOC - Permit Finaled6/5/20206/5/20206/5/2020PPASS
DetailsMike Jordan
All issues resolved. Driveway and fire apperatus turnaround have been paved and are per approved plan.
BLD-Final5/28/20205/29/20205/29/2020PFAIL
DetailsTell Riley
Racheal Phone #: ###-####//CN issued//need address posted on home//need landing at exterior garage door//provide zoning approval of gravel drive and no hard surface at front//provide fire approval of entrance and turnaround area//
BLD-Framing/Rough-in2/10/20202/11/20202/11/2020APASS
DetailsMike Jordan
Final framing inspection for cover. Call with any questions. Thanks! Phone #: ###-#### Inspection requested via web by Rachael Moore. All issues have been resolved.
BLD-Energy code compliance2/11/20202/11/20202/11/2020APASS
DetailsMike Jordan
Final framing inspection for cover. Call with any questions. Thanks! Phone #: ###-#### Inspection requested via web by Rachael Moore
BLD-Framing/Rough-in2/9/20202/10/20202/10/2020PDONE
DetailsMike Jordan
Call to meet to go over truss build. Thanks! Phone #: ###-#### Inspection requested via web by Rachael Moore
BLD-Framing/Rough-in2/7/20202/7/20202/7/2020AFAIL
DetailsMike Jordan
Framing and rough in and reinspect for bracing hold downs. Please call with any questions. Thanks! Phone #: ###-#### Inspection requested via web by Rachael Moore. Fire block around duct work at ceiling. Provide additional 2x6 studs under 3 ply CG1 truss. Install straps at portal frame. Provide hangar for 2ply A8 truss. Provide addtional 2x studs in garage at beam. Install h2.5 on trusses. Complete lateral bracing on A8 truss. Provide truss repair for missed bearing on trusses at west wall at fron patio cover. Correction notice posted. ok to insulate.
BLD-Conference10/22/201910/23/201910/23/2019APART
DetailsMike Jordan
Wall bracing/sheeting Phone #: ###-#### Inspection requested via web by Rachael Moore. Needs to install the missing hold downs on south end of house as noted on the approved plans. Ok to cover the exterior.
BLD-Foundation4/8/20194/9/20194/9/2019APART
DetailsMike Jordan
Dan Phone #: ###-#### Inspection requested via web by Rachael Moore
BLD-Concrete3/29/20194/1/20194/1/2019APART
DetailsMike Jordan
Dan Phone #: ###-####
BLD-Footing3/28/20193/28/20193/28/2019PNR
DetailsJim Sly
Late afternoon if possible please. Please call Dan at listed number. Same site as BLD19-00698 inspection request. Phone #: ###-#### Inspection requested via web by Rachael Moore