Permit Information
Permit NumberBLD19-01210
StatusFinaled
Name SMALL ACREAGE SOLUTIONS LLC
Site Address 1016 W TARGEE ST
Project NameFord addition
Customer Number 
ePlanReviewNo
Description
Permit for 30'x60' addition (one story with bonus space above) that adds 1,566sq of garage and 1,200sq' of living space, including two Full Bathrooms & a Bedroom. All work per plans, notations, attachments, local codes & ordinances. Separate electrical, plumbing & mechanical permits required. **JAB**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/4/20203/5/20203/5/2020APASS
DetailsJim Storey
Please call and I can meet you on site. Phone #: ###-#### Inspection requested via web by Chad Queen
DOC - Permit Finaled3/5/20203/5/20203/5/2020PPASS
DetailsJim Storey
BLD-Aging Inspection2/21/20202/21/20202/21/2020 PASS
DetailsJim Storey
BLD-Energy code compliance10/9/201910/10/201910/10/2019APASS
DetailsJim Storey
Drywall will be loaded in the building tomorrow afternoon.
Thank you Phone #: ###-#### Inspection requested via web by Chad Queen
BLD-Framing/Rough-in10/2/201910/2/201910/2/2019APASS
DetailsJim Storey
c/n made ok/ foam insulation roof ok/
BLD-Framing/Rough-in10/1/201910/2/201910/2/2019APASS
DetailsJim Storey
Chad Phone #: ###-#### under floor ok to cover pending trade insp.
BLD-Framing/Rough-in9/23/20199/23/20199/23/2019PPART
DetailsJim Storey
Documents and Manual J on site by stair case Phone #: ###-#### Inspection requested via web by Chad Queen fire blk cielling at chase box/airseal all vertcal penatrations ie wire , pipes ect./finsh duct ceilling fur down.
BLD-Wall Bracing7/10/20197/12/20197/12/2019APASS
DetailsJim Storey
Steve Phone #: ###-####
BLD-Foundation6/21/20196/21/20196/21/2019PPEND
DetailsJim Storey
Chad Phone #: ###-#### p/l
BLD-Concrete6/21/20196/21/20196/21/2019PPASS
DetailsJim Storey
Steve Phone #: ###-#### r value ok under slab
BLD-Foundation6/14/20196/14/20196/14/2019PFAIL
DetailsJim Storey
Chad-foundation wall Phone #: ###-####// ......No property pins located. No string lines pulled. Unable to determine if setbacks were met. If Contractor proceeds to pour foundation.......they are continuing at own risk.// min r-10 under slab non value on product do not place until reinspect bfor prop. line and r value are verified.
BLD-Foundation5/21/20195/22/20195/22/2019PPART
DetailsJim Sly
Chad Phone #: ###-####
See previous Footing inspection notes.......
BLD-Footing5/16/20195/20/20195/20/2019PPART
DetailsJim Sly
Chad Phone #: ###-####
Called contractor......No property pins located. No string lines pulled. Unable to determine if setbacks were met. If Contractor proceeds to pour foundation.......they are continuing at own risk.