BLD-Final | 4/20/2020 | 4/20/2020 | 4/20/2020 | P | PASS |
Brandon Shaw
|
|
|
HVAC is now completed and signed off Phone #: ###-#### Inspection requested via web by Larry Kincaid
|
DOC - Permit Finaled | 4/20/2020 | 4/20/2020 | 4/20/2020 | P | PASS |
Brandon Shaw
|
|
|
|
BLD-Final | 4/1/2020 | 4/2/2020 | 4/2/2020 | P | PART |
Brandon Shaw
|
|
|
Temp C of O ia approved for 30 days ending 4Mar20... Needs MEC19-04186 final, no other issues...
|
BLD-Final | 4/1/2020 | 4/2/2020 | 4/2/2020 | A | CANC |
Brandon Shaw
|
|
|
I did a pre-conference walk through with Tell Riley for this project and we are now ready for the final. He might be best to do the final since we already went through all the items. Please call prior to coming to the site so I can make sure and be their. Thanks, Phone #: ###-#### Inspection requested via web by Larry Kincaid
|
BLD-Conference | 3/24/2020 | 3/24/2020 | 3/24/2020 | P | DONE |
Tell Riley
|
|
|
I would like to schedule a conference or job site meeting to discuss all items we will need to get the project final inspection Phone #: ###-#### Inspection requested via web by Larry Kincaid
|
BLD-Foundation | 1/13/2020 | 1/13/2020 | 1/13/2020 | P | PASS |
Brandon Shaw
|
|
|
Work in progress... Frost protection is reqired...
|
BLD-Footing | 1/8/2020 | 1/9/2020 | 1/9/2020 | A | PASS |
Brandon Shaw
|
|
|
Need rebar inspection for retaining wall footers Thanks, Inspection requested via web by Larry Kincaid
|
BLD-Foundation | 12/23/2019 | 12/26/2019 | 12/26/2019 | P | PASS |
Brandon Shaw
|
|
|
Work in progress...
|
BLD-Footing | 12/18/2019 | 12/19/2019 | 12/19/2019 | A | PASS |
Brandon Shaw
|
|
|
need footing rebar inspection at retaining wall Inspection requested via web by Larry Kincaid
|
BLD-Energy code compliance | 11/22/2019 | 11/22/2019 | 11/22/2019 | P | PASS |
Brandon Shaw
|
|
|
OK to cover...
|
BLD-Wall cover | 11/22/2019 | 11/22/2019 | 11/22/2019 | P | CANC |
Brandon Shaw
|
|
|
Inspection requested via web by Larry Kincaid
|
BLD-Framing/Rough-in | 11/18/2019 | 11/19/2019 | 11/19/2019 | A | PASS |
Brandon Shaw
|
|
|
Inspection requested via web by Larry Kincaid
|
BLD-Energy code compliance | 11/18/2019 | 11/19/2019 | 11/19/2019 | A | PART |
Brandon Shaw
|
|
|
Air/foam seal...
|
BLD-Foundation | 11/18/2019 | 11/18/2019 | 11/18/2019 | P | PART |
Brandon Shaw
|
|
|
Work in progress...
|
BLD-Framing/Rough-in | 11/18/2019 | 11/18/2019 | 11/18/2019 | P | CANC |
Brandon Shaw
|
|
|
>> Inspection requested via web by Larry Kincaid Inspection cancelled from web by: Larry Kincaid
|
BLD-Footing | 11/12/2019 | 11/13/2019 | 11/13/2019 | A | PASS |
Brandon Shaw
|
|
|
rebar inspection for retaining wall footer
Thanks, Inspection requested via web by Larry Kincaid
|
BLD-Concrete | 10/24/2019 | 10/24/2019 | 10/24/2019 | P | PASS |
Brandon Shaw
|
|
|
Work in progress... West wall...
|
BLD-Framing/Rough-in | 10/7/2019 | 10/8/2019 | 10/8/2019 | A | PART |
Brandon Shaw
|
|
|
Need to schedule an inspection for the roof underside so we can do a spray foam insulation before we install fire sprinkler lines.
|
BLD-Footing | 9/26/2019 | 9/27/2019 | 9/27/2019 | A | PASS |
Brandon Shaw
|
|
|
Work in progress...
|
BLD-Wall Bracing | 9/20/2019 | 9/23/2019 | 9/23/2019 | A | PART |
Brandon Shaw
|
|
|
Exterior only... Interior shear and hold downs to be completed before framing rough-in...
|
BLD-Foundation | 7/23/2019 | 7/24/2019 | 7/24/2019 | A | PASS |
Dave Hannah
|
|
|
Inspection requested via web by Larry Kincaid
|
BLD-Footing | 7/17/2019 | 7/18/2019 | 7/18/2019 | A | PASS |
Brandon Shaw
|
|
|
need rebar inspection for footings. Concrete pump and concrete delivery is scheduled for 11:00am. Thursday thanks Phone #: ###-#### Inspection requested via web by Larry Kincaid
|
BLD-Foundation | 6/26/2019 | 6/26/2019 | 6/26/2019 | P | PART |
Tony Young
|
|
|
rebar inspection for basement walls Phone #: ###-#### Inspection requested via web by Larry Kincaid// work in progress on the basement walls,, ok
|
BLD-Footing | 6/14/2019 | 6/14/2019 | 6/14/2019 | P | PART |
Tony Young
|
|
|
Jerry Phone #: ###-####,, basement footing ok
|
BLD-Footing | 6/13/2019 | 6/14/2019 | 6/14/2019 | A | PART |
Tony Young
|
|
|
Jerry Phone #: ###-####,, basement footing
|