Information based on query as of Tuesday, May 14, 2024.
Permit Information
Permit NumberBLD19-01411
StatusFinaled
Name MJH INVESTMENTS
Site Address 10861 W CRANBERRY CT
Project Name10861 Cranberry SFR
Customer Number 
ePlanReviewYes
Description
Permit for the construction of a new 2297 sq. ft., two story (first story 1808 sq. ft., second story 489 sq. ft.) single family dwelling with 3 bedrooms, 3 bathrooms, approximately 207 sq. ft. of covered patio/porch and a 554 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. R-1C zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Blower Door Test Results10/16/201910/16/201910/16/2019PDONE
DetailsTell Riley
4.34 ACH 50
1712 cfm @ 50 pa
BLD-Final10/16/201910/16/201910/16/2019PPASS
DetailsTell Riley
Vinny Phone #: ###-####//corrections made//
DOC - Permit Finaled10/16/201910/16/201910/16/2019PPASS
DetailsTell Riley
BLD-Final9/27/201910/1/201910/1/2019AFAIL
DetailsTell Riley
Vinny Phone #: ###-####//need to seal penetrations at garage house separation wall//add insulation to crawl access door//no attic access 2nd level//add light in closet under stairs//
BLD-Energy code compliance7/24/20197/25/20197/25/2019APASS
DetailsTell Riley
Vinny Phone #: ###-####
BLD-Energy code compliance7/22/20197/23/20197/23/2019ACANC
DetailsTell Riley
Vini Phone #: ###-####
BLD-Framing/Rough-in7/22/20197/23/20197/23/2019APASS
DetailsTell Riley
Vini Phone #: ###-####//ok to insulate only//add hanger at girder for beam//add fireblocking at stairway//will check at energy//
BLD-Framing/Rough-in7/17/20197/18/20197/18/2019ANR
DetailsTell Riley
Vinnie Phone #: ###-####//need plumbing rough in passed///
BLD-Energy code compliance7/17/20197/18/20197/18/2019ACANC
DetailsTell Riley
Vinnie Phone #: ###-####
BLD-Wall Bracing7/1/20197/2/20197/2/2019APASS
DetailsTell Riley
Vinnie Phone #: ###-####//corrections made//
BLD-Wall Bracing6/25/20196/27/20196/27/2019PPART
DetailsTell Riley
Kerry Phone #: ###-####//add blocking on second story..finish nailing second story//fasten OSB to sill plate all the way around the first floor//
BLD-Foundation5/23/20195/24/20195/24/2019PPASS
DetailsJim Sly
Dane Phone #: ###-####
BLD-Foundation5/22/20195/23/20195/23/2019PPASS
DetailsJim Sly
Dane Phone #: ###-####
BLD-Foundation5/20/20195/21/20195/22/2019PNR
DetailsJim Sly
Dane Phone #: ###-####
BLD-Footing5/15/20195/16/20195/16/2019APASS
DetailsJim Sly
Dane Phone #: ###-####
BLD-Footing5/14/20195/15/20195/15/2019PPASS
DetailsBrandon Shaw
Work in progres...