Permit Information
Permit NumberBLD19-01970
StatusFinaled
Name D & D HANDYMAN SERVICES LLC
Site Address 800 W IDAHO ST Unit: STE 200
Project Name8th Street Entertainment
Customer Number 
ePlanReviewYes
Description
(8TH STREET ENTERTAINMENT – TENANT SPACE EXPANSION) (10-29-19 PLAN MODIFICATION TO PROVIDE RAISED SEATING AREAS ON TWO SIDES OF THE DANCE FLOOR, TO RECONFIGURE A BAR, AND TO REVISE THE OCCUPANT LOAD OF THE TENANT SPACE. EACH RAISED SEATING AREA WILL BE SERVED BY A RAMP. A MULTI-PANEL POCKETING DOOR WILL BE REPLACED WITH AN OVERHEAD DOOR HAVING LAMINATED GLASS.) The fire sprinkler system is used for building area increase, story increase, for fire area, and for fire flow. To expand an existing 4,956 square foot bar (night club) by about 3,781 square feet into adjacent areas on the 2nd story. After the expansion, this tenant space will have a total floor area of about 8,737 square feet. The 2nd story also has a 1,319 square foot storage room that is part of a 1st story tenant space, an 865 square foot common area, and 553 square feet of stairways. Work is to include interior nonbearing walls, an expanded Men’s toilet room accessible to the disabled, a new Women’s toilet room accessible to the disabled, converting an existing toilet room to comply as an assisted-use toilet room, new booth seating, pool tables, dart boards, shuffle board tables, a new pocked folding partition, furniture, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 (including quick-response heads where required) and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/24/20201/27/20201/27/2020PPASS
DetailsDave Hannah
DO NOT RESCHEDULE IF NOT GC CALLING Ryan Phone #: ###-####
FIRE-Final Inspection1/24/20201/27/20201/27/2020APASS
DetailsJim Page
Previously noted items have been corrected, fnal life safety inspection complete, permit sign off card not available at time of inspection no signatures provided.


DO NOT RESCHEDULE WITH IF NOT GC CALLING Ryan Phone #: ###-####
FIRE-Final Inspection12/31/201912/31/20191/1/2020PPART
DetailsJim Page
Partial final inspection for life fire safety complete. Fire sprinkler inspection is complete, fire alarm inspection is partially complete, reference notes under FIR permit for fire alarms items needed to be completed, fire extinguishers are placed with current inspection tags (Inspection tags on fire extinguishers expires in January). 14 day TCO for life fire safety authorized by Ron Johnson with Boise Fire, permit sign off card not provided at time of inspection.

RC Phone #: ###-####
BLD-Final12/31/201912/31/201912/31/2019PPEND
DetailsDave Hannah
RC Phone #: ###-#### ok for a 15 day tco as per fire
BLD-Conference12/26/201912/27/201912/27/2019ADONE
DetailsDave Hannah
RC Phone #: ###-####
BLD-Conference11/4/201911/5/201911/5/2019ADONE
DetailsDave Hannah
call for access- RC Phone #: ###-####
BLD-Framing/Rough-in10/29/201910/30/201910/30/2019APASS
DetailsDave Hannah
Jake Phone #: ###-####
BLD-Framing/Rough-in10/21/201910/21/201910/21/2019PPASS
DetailsDave Hannah
Jake Phone #: ###-#### rest rooms walls ok and corrador walls ok
BLD-Framing/Rough-in10/16/201910/17/201910/17/2019APART
DetailsTell Riley
jAKE Phone #: ###-####//ok to cover "Coat storage areas// ok to cover infill walls at corridor//bathroom concealed space will need fire blocking at top and penetrations through floor//add blocking for hand rails//
BLD-Framing/Rough-in10/1/201910/2/201910/3/2019APART
DetailsDave Hannah
Jake- inspection for office and green room and girls bathroom Phone #: ###-#### ok to cover green rm and office after elec r/i