Information based on query as of Wednesday, May 15, 2024.
Permit Information
Permit NumberBLD19-02030
StatusFinaled
Name HHS CONSTRUCTION LLC
Site Address 2421 S TRAPPER PL
Project NameHarris North Lot 4 Block 1
Customer Number 
ePlanReviewYes
Description
***W.U.I. FOOTHILLS LOT ZONE A; CLASS "A" ROOF AND NON-COMBUSTIBLE EXTERIOR MATERIALS REQUIRED*** Permit for the construction of a new 3590 sq. ft., two story (first story 1887 sq. ft., second story 1703 sq. ft.) single family dwelling with 5 bedrooms, 3.5 bathrooms, approximately 431 sq. ft. of covered patio/porch and a 993 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. SP-01 zoning and setbacks per planning. *** RDP*** ***SPRINKLERS ARE NOT REQUIRED***LGMA letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.

Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/27/201912/30/201912/30/2019APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Kyle Seick
DOC - Permit Finaled12/30/201912/30/201912/30/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results12/30/201912/30/201912/30/2019ADONE
DetailsBrandon Shaw
ACH50- 3.92
BLD-Other10/2/201910/2/201910/2/2019PPASS
DetailsBrandon Shaw
Les-fire soffit Phone #: ###-####
BLD-Energy code compliance9/26/20199/26/20199/26/2019PPASS
DetailsBrandon Shaw
les Phone #: ###-####
BLD-Framing/Rough-in9/23/20199/23/20199/23/2019PPASS
DetailsBrandon Shaw
Les Phone #: ###-####
BLD-Framing/Rough-in9/5/20199/6/20199/6/2019ACANC
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
BLD-Wall Bracing8/20/20198/21/20198/20/2019APART
DetailsBrandon Shaw
First floor only...
BLD-Foundation7/23/20197/23/20197/23/2019PPASS
DetailsBrandon Shaw
Work in progress...
BLD-Footing7/22/20197/22/20197/22/2019PPASS
DetailsBrandon Shaw
Work in progress...