Information based on query as of Friday, May 3, 2024.
Permit Information
Permit NumberBLD19-02617
StatusTemporary Occupancy
Name PERRYMAN CONSTRUCTION MANAGEMENT IN
Site Address 7353 N LUCY ROSE LN
Project NameEaglehawk Fourplex - Bldg 1
Customer NumberBLD19-02617 TO BLD19-02622
ePlanReviewYes
Description
(EAGLEHAWK FOURPLEX MULTIFAMILY APARTMENTS – 7353 N. LUCY ROSE ST. – BUILDING 1) (6 BUILDING PERMITS UNDER BLD19-02617 IN EPLAN) //2-12-2020 PLAN MODIFICATION TO REPLACE MECHANICAL DESIGN WITH MANUAL S, J, ADJUSTMENTS TO MECHANICAL EQUIPMENT AND DUCTWORK. Jg.// Permit for the construction of a 4,852 sq. ft. 2-story four-unit apartment building. This building is one of six buildings within a multi-family development. Work to include general site work and the construction of the new building per the approved plans, attached engineering and plan review report. Note: Special Inspections Required see form 310. This building is to be fully fire sprinklered with an NFPA 13-R system as required for residential occupancy. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/25/20206/26/20206/26/2020APASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Final6/24/20206/25/20206/25/2020PPART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson// ok pending address posting in units..
BLD-Blower Door Test Results6/25/20206/25/20206/25/2020PDONE
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson// average 5.7
FIRE-Final Inspection6/24/20206/25/20206/25/2020APASS
DetailsTroy Cobbley
Life safety passed. Inspection by Greg.

Phone #: ###-#### Inspection requested via web by bill gullickson
FIRE-Final Inspection6/23/20206/24/20206/24/2020AFAIL
DetailsJim Page
Correctly repair holes that were next to fire sprinkler heads in furnace closets. CPVC pipe is exposed in side entry closet under the stairs.

Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Final6/23/20206/24/20206/24/2020ANR
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Energy code compliance4/14/20204/15/20204/16/2020PPASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Energy code compliance4/10/20204/14/20204/14/2020PPEND
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson// needs re-inspection for fire
BLD-Framing/Rough-in4/8/20204/9/20204/9/2020PPASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Framing/Rough-in4/8/20204/8/20204/8/2020PNR
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson
BLD-Framing/Rough-in4/3/20204/8/20204/8/2020AFAIL
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson// nail hangers off as needed, strap plates as needed, overlap truss braces as needed,, nail hing studs as needed, etc, see paint
BLD-Wall Bracing4/1/20204/2/20204/2/2020APASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by bill gullickson,, exterior was ok to cover
BLD-Wall Bracing3/25/20203/26/20203/26/2020APEND
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by bill gullickson. Needs to resolve with Tony.
BLD-Wall Bracing3/4/20203/5/20203/5/2020ACANC
DetailsTony Young
Exterior wall shear inspection. Cheers, Phone #: ###-#### >> Inspection requested via web by Nic Van Diepen Inspection cancelled from web by: Nic Van Diepen
BLD-Wall Bracing2/14/20202/18/20202/18/2020ACANC
DetailsTony Young
Ed Phone #: ###-#### Inspection cancelled from web by: Nic Van Diepen
BLD-Energy code compliance11/26/201911/26/201911/26/2019PPASS
DetailsTony Young
Foundation rigid insulation. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Energy code compliance11/25/201911/26/201911/26/2019APART
DetailsTony Young
Foundation wall rigid insulation. Thanks, Phone #: ###-#### Inspection requested via web by Nic Van Diepen
BLD-Foundation11/19/201911/20/201911/20/2019PPASS
DetailsTony Young
Ryan Phone #: ###-####
BLD-Footing11/19/201911/20/201911/20/2019APART
DetailsTony Young
Ryan Phone #: ###-####