Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberBLD19-03460
StatusFinaled
Name BLACKROCK HOMES LLC
Site Address 1525 S BOULDER VIEW LN
Project Name68-1 WSV
Customer NumberGATE CITY
ePlanReviewYes
Description
**W.U.I. FOOTHILLS ZONE A CLASS "A" ROOF AND NON-COMBUSTIBLE EXTERIOR SIDING REQUIRED** **PASSES USING UA TRADE OFF** Permit for the construction of a new 2622 sq. ft., two story (first story 2168 sq. ft., second story 454 sq. ft.) single family dwelling with 3 bedrooms, 2 bathrooms, approximately 226 sq. ft. of covered patio/porch and a 652 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. ***SPRINKLERS ARE NOT REQUIRED***LGM A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/13/20207/16/20207/16/2020APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Clint Wall
DOC - Permit Finaled7/16/20207/16/20207/16/2020PPASS
DetailsBrandon Shaw
DOC - Permit Finaled7/13/20207/13/20207/13/2020PPASS
DetailsMike Jordan
4 (This activity was added in error so we have changed the case status back to Issued.)
BLD-Final7/6/20207/13/20207/13/2020AFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Clint Wall. Handrail does not extend to first or last riser. Everything else ok. (This activity was added in error so we have changed the case status back to Issued.)
BLD-Blower Door Test Results7/6/20207/13/20207/13/2020ADONE
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Clint Wall
BLD-Energy code compliance4/29/20205/6/20205/6/2020APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Clint Wall
BLD-Framing/Rough-in4/29/20205/4/20205/4/2020APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Clint Wall
BLD-Wall Bracing3/27/20203/27/20203/27/2020PPART
DetailsTell Riley
Jorge Phone #: ###-####//need to add hot dip galvanized nails to pt//add blocking///add straps on 2nd story//
BLD-Wall Bracing3/26/20203/26/20203/26/2020PCANC
DetailsJim Storey
jorge Phone #: ###-#### fee not paided
BLD-Wall Bracing3/25/20203/25/20203/25/2020PCANC
DetailsMike Jordan
jorge Phone #: ###-####086
BLD-Wall Bracing3/24/20203/25/20203/25/2020AFAIL
DetailsMike Jordan
Jorge Phone #: ###-####. No city approved plans on site. reinspection fee issued.
BLD-Foundation12/10/201912/10/201912/10/2019APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Edgar Sanchez
BLD-Footing12/4/201912/5/201912/5/2019APASS
DetailsBrandon Shaw
Work in progress...