ELE-Aging Inspection | 2/7/2019 | 2/7/2019 | 2/12/2019 | | PASS |
Mark Moncarr
|
|
|
Existing home demolished, and new home constructed on parcel.
|
Final | 2/12/2019 | 2/12/2019 | 2/12/2019 | P | PASS |
Mark Moncarr
|
|
|
Talked to Terry with Stephens Electric on 2/12/19. Drove to site and verified that house was demolished and a new home is now on property.
|
Permanent Service | 10/15/2014 | 10/15/2014 | 10/15/2014 | P | FAIL |
Rock A. Hudson
|
|
|
ACCESS CODE 6500
Any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren 250.53(D)(1)(2)- Metal Underground Water Pipe. If used as a grounding electrode, metal underground water pipe shall meet the requirements of 250.53(D)(1) and (D)(2). (1) Continuity. Continuity of the grounding path or the bonding connection to interior piping shall not rely on water meters or filtering devices and similar equipment. (2) Supplemental Electrode Required. A metal underground water pipe shall be supplemented by an additional electrode of a type specified in 250.52(A)(2) through (A)(8). Clamp loose on poping system and con not verify additional rod wire is under deck
|