ELE-Aging Inspection | 3/21/2019 | 3/21/2019 | 3/22/2019 | | PASS |
Tom Saunders
|
|
|
final scheduled...see notes
|
Final | 3/22/2019 | 3/22/2019 | 3/22/2019 | P | PASS |
Tom Saunders
|
|
|
corrections done under permit ELE17-01230 by different contractor...finaling permit to close
|
Conference | 4/12/2017 | 4/17/2017 | 4/17/2017 | A | DONE |
Daryl DeGrange
|
|
|
New general contactor would like to meet to discuss job history and next step to final permits. Informed 327 all previous ele contractors refuse work due to lack of payment. Tony ###-#### called this number and Julie answered. Julie ###-#### from notes on 4-12-17 inspections. Spoke with New General Contractor, discussed New Electrical contractor requirements
|
Final | 4/11/2017 | 4/12/2017 | 4/12/2017 | A | NR |
Rock A. Hudson
|
|
|
Tony Phone #: ###-#### Work yet to finish. See RI notes
|
Electrical Rough-In | 4/11/2017 | 4/12/2017 | 4/12/2017 | A | FAIL |
Rock A. Hudson
|
|
|
Juile ###-#### Tony Phone #: ###-#### Homeowner requested inspections. All-star Electric has open permit ###-####. Electrical contractor only one to request inspections under permit purchased. 210.52- Door to be framed in at entrance to bedroom shall have a receptacle outlet located with in 6'. No point measured along floor line shall be greater than 6' fram a receptacle outlet. 300.15- All wiring shall terminate in a box with cover. Old AC location next to stairway outdoors and misc covers needed inside. 400.8- Flexible cords shall not pass thru doorway, walls, or ceiling. Relocate sump pump receptacle to inside room. 410.16- Luminaires located in closets and storage area shelves shall be totally enclosed type. New closet to be built in bed with 2 cans with open type and open lamp in storage area. 422.30- Water heater shall have a disconnecting means located with in sight. Lock out acceptable as per 110.25.
|