Information based on query as of Sunday, May 19, 2024.
Permit Information
Permit NumberFIR11-00334
StatusFinaled
Name ABSOLUTE FIRE PROTECTION
Site Address 4153 W QUAIL HILL CT
Project NameCanyon Crest Homes - Beaumont
Customer Number 
ePlanReviewNo
Description
The Fire Sprinkler Scope of work consists of providing a NFPA 13D sprinkler system for a new home. In addition, one row of sprinklers is required for the common wall between the garage and the home. The system is a 1” tree with a 1½” riser in the garage.

The underground supply is under permit in FIR11-00305

Building Department Scope:

Permit for the construction of a new 3,388 sq. ft., two stories (first story 2,926 sq. ft., second story 462 sq. ft.) with 4 bedrooms, 3 1/2 bathrooms, approximately 252 sq. ft. of covered patio/porch and a 1,270 sq. ft. attached garage per the approved plans, plan review report and any notations. Fire Protection: A residential modified 13D sprinkler system IS required. In addition to the requirements of NFPA 13D there shall be one additional row of sprinklers at the separation wall between the garage and living space. This structure is located in WUI zone A. A letter from the applicant’s geotechnical engineer indicating that the footing sub-grade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Terry Records at 384-3946. R-1C zoning and setbacks per planning. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/21/201110/21/201110/21/2011APASS
DetailsTroy Cobbley
permit finaled
INSP-Final Inspection10/18/201110/20/201110/21/2011PCANC
DetailsTroy Cobbley
Overbooked. Rescheduled for tomorrow.
INSP-Sprinkler Rough-in8/22/20118/23/20118/23/2011APASS
DetailsTroy Cobbley
The sprinkler piping in the master bath can now be covered. I let the sprinkler contractor know that the outside alarm bell can not be installed where the builder currently has it located. It needs to be located on the front of the house or relocated to the east end of the house which is closer to the street. Tim Frost was going to contact the builder and let him know this same information.
INSP-Sprinkler Rough-in8/19/20118/22/20118/22/2011APART
DetailsTroy Cobbley
The sprinkler piping is ok to cover except for the master bathroom. The pendant coverage in the master bathroom is blocked by a soffit over the bathtub.
INSP-Supply line flush8/19/20118/22/20118/22/2011APASS
DetailsTroy Cobbley
Underground flush passed
INSP-Sprinkler Rough-in/Hydro8/18/20118/19/20118/19/2011PCANC
DetailsForrest France
Overbooked