Permit Information
Permit NumberMEC19-02078
StatusFinaled
Name PREMIER HEATING & AIR CONDITIONING
Site Address 2307 N 21ST ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: new vac system and wood burning fireplace
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled11/4/201911/4/201911/4/2019PPASS
DetailsBen Livingston
Final11/3/201911/4/201911/4/2019PFAIL
DetailsBen Livingston
Inspection requested via web by Don Dowers
- need locking caps on condencer -
Rough-in6/20/20196/21/20196/21/2019APASS
DetailsBen Livingston
this is for wood burning fireplace rough in only. Inspection requested via web by Don Dowers
Pressure Test5/29/20195/30/20195/30/2019APASS
DetailsEric Strole
Inspection requested via web by Don Dowers
Pressure Test5/29/20195/29/20195/29/2019PFAIL
DetailsEric Strole
20 lb gas test pass. Cannot strap gas-tite in vertical walls.
Rough-in5/28/20195/29/20195/29/2019PPASS
DetailsEric Strole
Inspection requested via web by Don Dowers
Rough-in5/27/20195/28/20195/28/2019PFAIL
DetailsBen Livingston
Inspection requested via web by Don Dowers
manual J calls for 6" fresh air not 4" 5lb flue okay
Pressure Test5/28/20195/28/20195/28/2019PFAIL
DetailsBen Livingston
Inspection requested via web by Don Dowers
flash shield fittings not installed per manufacturers instalation instructions, need to use factory approved stricker plates, cannot attach gas flex inside of a wall, need to repressure test again
Rough-in5/24/20195/28/20195/27/2019ACANC
DetailsBen Livingston
>> Inspection requested via web by Don Dowers Inspection cancelled from web by: Don Dowers