Permit Information
Permit NumberMEC19-04004
StatusFinaled
Name ICON AIR
Site Address 7720 E BRIAN AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: Installing HVAC
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/9/201912/9/201912/9/2019PPASS
DetailsJack Reynolds
Reinspect Phone #: ###-#### Inspection requested via web by Randy Hart
- final ok
Final12/5/201912/6/201912/5/2019PCANC
DetailsJack Reynolds
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
Final12/4/201912/5/201912/5/2019AFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Randy Hart
- need to see combustion opening in doors at laundry room and mech closet for final
- locking caps at A/C
- line set UV protection and line set penetration sealed
Rough-in10/16/201910/16/201910/16/2019PPASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Randy Hart
- R/I ok
- lower combustion air in laundry room door will be seen at final
Rough-in10/15/201910/16/201910/16/2019ACANC
DetailsJack Reynolds
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
Rough-in10/11/201910/15/201910/15/2019AFAIL
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Randy Hart
- need city approved man j onsite
- fresh air needs ran to furnace return plenum
- line set insulation at floor penentrations needs fixed
- combustion air for furnace needs to be per IECC R402.4.4 or combustion air needs taken through high/low grilles inside place
Pressure Test10/11/201910/15/201910/15/2019APASS
DetailsJack Reynolds
Phone #: ###-#### Inspection requested via web by Randy Hart
- 20lb gas pressure test ok
- tagged meter location