Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberPLM18-04126
StatusFinaled
Name CLOVERDALE PLUMBING CO
Site Address 2758 S FEATHERLY WAY
Project Name 
Customer Number49468
ePlanReviewNo
Description
Alteration: Replace power vent water heater
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Water Heater Final10/17/201810/18/201810/17/2018APASS
DetailsDan Ediger
Re-inspection Phone #: ###-#### Inspection requested via web by Heidi Lukecart
Water Heater Final10/10/201810/11/201810/11/2018PNH
DetailsDan Ediger
Re-inspection. Please call Martin with Ada County with 30 min lead time to let you in. ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
No access tagged door
Water Heater Final9/28/20189/28/20189/28/2018PFAIL
DetailsDan Ediger
Martin is maintenance Coordinator ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
1. The t&p drain requirs an air gap.
2. The condensate drain must be trapped.
3 Add a drip leg to the gas line connection