Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberPLM19-04555
StatusFinaled
Name STEVES PLUMBING SERVICE
Site Address 2741 W AIRPORT WAY
Project NameHoya Optical Labs TI
Customer Number 
ePlanReviewNo
Description
Alteration: Rough Plumbing of drain and water lines in order to add sink for a tenant improvement. I spoke with Dan and Daryl today 10/22/19 about the situation and they are aware of the wet venting issue with the floor drain and the slab on grade building
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/28/201910/29/201910/29/2019APASS
DetailsEric Strole
lock box code 1976 or 1967 cant remember Phone #: ###-#### Inspection requested via web by Jeffrey Hankins
Plumbing Rough-in10/23/201910/24/201910/24/2019APASS
DetailsMatt Wrobel
box code 1967 Phone #: ###-#### Inspection requested via web by Jeffrey Hankins
all items addressed rough pass ok to cover
Plumbing Rough-in10/22/201910/23/201910/23/2019PFAIL
DetailsDan Ediger
call jeff with any questions Phone #: ###-#### Inspection requested via web by Jeffrey Hankins
1. Hard pipe the t&p. Must remove the flex.
2. Install a shut-off valve on the cold side of the water heater.
3. Pex pipe cannot be installed within 18" of the water heater.
4. Must use a shielded band on the dwv within the building.