Permit NumberPLM20-00350
StatusFinaled
Name KNIGHT PLUMBING & CONSTRUCTION INC
Site Address 1105 S FEDERAL WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration: install bathroom, sink, toilet
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/9/20203/10/20203/10/2020APASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Michael Klaas
Card not on site to sign3/10/20203/10/20203/10/2020PPASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Michael Klaas
Final3/8/20203/9/20203/9/2020AFAIL
DetailsMatt Wrobel
Phone #: ###-#### Inspection requested via web by Michael Klaas
1. publicly accessable lavatories require tempering valves
2. double check needs to be tested and certified
Final3/3/20203/4/20203/4/2020ANH
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Michael Klaas-No access, left notice.
Plumbing Rough-in2/3/20202/3/20202/3/2020PPASS
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Michael Klaas
Plumbing Rough-in1/31/20201/31/20201/31/2020PFAIL
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Michael Klaas-Need to use a mission coupling from cast iron to abs in groundwork connection.
Plumbing Rough-in1/30/20201/30/20201/30/2020PFAIL
DetailsDan Ediger
Phone #: ###-#### Inspection requested via web by Michael Klaas.
Heat tape isn't an approved assembly for freeze protection in an attic.
Pipe must be attached to the joist, visqueen under the pipe, insulation bats over the pipe attached to the joists.
Plumbing Rough-in1/29/20201/30/20201/30/2020AFAIL
DetailsDan Ediger
Phone #: ###-#### Inspection requested via web by Michael Klaas
1. Cannot run the water lines in the cold attic without freeze protection assembly.
2. An expansion tank will be required on trim.
3. Verify ADA WC r-in.